Peripapillary choroidal thickness assessed using automated choroidal segmentation software in an Asian population
Preeti Gupta1, Tian Jing2, Pina Marziliano2
1Singapore Eye Research Institute and Singapore National Eye Centre, Singapore, Singapore Department of Ophthalmology, Yong Loo Lin School of Medicine, National University of Singapore and National University Health System, Singapore, Singapore.
This study used automated software to measure peripapillary choroidal thickness (PPCT) in Asian eyes. Shorter axial length, younger age, lower triglycerides, and diabetes were linked to thicker PPCT.
Area of Science:
- Ophthalmology
- Medical Imaging
- Choroidal Imaging
Background:
- Peripapillary choroidal thickness (PPCT) is a key indicator in ocular health.
- Accurate measurement of PPCT is crucial for diagnosing and monitoring various eye conditions.
- Previous methods for PPCT measurement had limitations in objectivity and automation.
Purpose of the Study:
- To objectively quantify peripapillary choroidal thickness (PPCT) in Asian eyes using spectral-domain optical coherence tomography (SD-OCT) with enhanced depth imaging (EDI).
- To evaluate systemic and ocular determinants influencing PPCT measurements.
- To validate a novel automated choroidal segmentation software for reliable PPCT assessment.
Main Methods:
- Recruited 520 subjects (1040 eyes) from the population-based Singapore Malay Eye Study.
- Utilized Spectralis SD-OCT with EDI for peripapillary choroidal thickness (PPCT) measurements.
- Employed a novel automated choroidal segmentation software for precise PPCT quantification.
Main Results:
- The automated software demonstrated excellent intra-session repeatability for PPCT measurements (ICC 0.9998-0.9999).
- The overall mean PPCT was 136.2±56.8 µm, with significant geographical variations across quadrants.
- Shorter axial length, younger age, lower triglyceride levels, and presence of diabetes were independently associated with thicker PPCT.
Conclusions:
- Novel automated choroidal segmentation software provides reliable objective PPCT measurements in a population-based setting.
- Key determinants of thicker PPCT include shorter axial length, younger age, lower triglyceride levels, and diabetes.
- These identified factors are important for interpreting Spectralis EDI SD-OCT-based PPCT measurements in clinical practice.
More Related Videos
03:47Retinal and Choroidal Thickness Changes in Populations with Helicobacter pylori Infection by Swept-Source Optical Coherence Tomography
Published on: November 1, 2024
04:25Author Spotlight: Bridging Gaps in Anatomy and Establishing a Foundation for Algorithmic Studies
Published on: December 15, 2023