Related Experiment Video
Updated: Apr 18, 2026

Transcanalicular Diode Laser-assisted Dacryocystorhinostomy for the Treatment of Primary Acquired Nasolacrimal Duct Obstruction
Published on: October 13, 2017
[Self-adjusting monocanalicular intubation for congenital lacrimal obstruction]
F J Alañón1, M A Alañón1, B Marín-González1
1Instituto Lagrimal Internacional, Jaén, España.
Objective:
To present our work with the Masterka self-adjusting monocanalicular intubation without nasal recuperation in congenital lacrimal obstruction in children over 12-months old.
Methods:
A total of 40 children between the ages of one and seven (average age 2.6 years) were consecutively operated on. The Masterka catheter has a flexible metal guide inside the silicone tube that covers it completely. The proximal end is fixed onto the lacrimal punctum by pushing it with a dilator or forceps. Its correct position was monitored and visually checked in real time during surgery in all cases.
Results:
The average surgery time, excluding anaesthetic, was 1.56min, ranging from 1.05 to 4min. The final success was 97.5%, considering absence of epiphora, disappearance of colouring in lacrimal meniscus, and mucopurulent secretion. The average follow-up time was 15 months (ranging from 7 to 21 months).
Conclusions:
Masterka intubation is an effective primary treatment. It is no more difficult than a simple catheter, since the surgical technique is similar, but with better functional results. It avoids the possibility of having to repeat the catheterization and it is easier to carry out than bicanalicular intubation, since there is no need to manipulate repeatedly or use surgical instruments in the inferior meatus, thus simplifying the process.
Related Concept Videos
Suctioning the Nasopharyngeal Airway
Equipment Required
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Administering Oxygen by Nasal Cannula
Nasal Cannulas
A nasal cannula is a lightweight tube split into two prongs placed in the nostrils,...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques