Related Experiment Video
Updated: Apr 18, 2026

Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Comprehensive two-dimensional gas chromatography and three-dimensional fluorometry for detection of volatile and
Tomasz Dymerski1, Jacek Namieśnik1, Kann Vearasilp2
1Department of Analytical Chemistry, Chemical Faculty, Gdańsk University of Technology, Gdańsk 80 952, Poland.
Abstract:
The volatile fractions of Cape gooseberry and blueberry were determined by headspace solid-phase microextraction coupled with comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry (HS-SPME/GC×GC-TOFMS). The highest amount of alcohol (51.8%), ester (32.8%) and carboxylic acid (6.9%) was in blueberry in comparison with gooseberry and oppositely ketones (14.7%), aldehydes (9.9%) and terpenes (8%) were found in gooseberry. The bioactive compounds and antioxidant capacities were higher in blueberries than in gooseberries. Three dimensional fluorescence emission spectrometry (3D-FL) was applied to determine and to compare experimentally found binding parameters of berries extracts with human serum albumin (HSA). The fluorescence quenching of HSA by polyphenols from berries was a result of the formation of a polyphenol-HSA complex. The binding abilities of berries were highly correlated with the bioactivity of polyphenols and volatile substances. The cluster analysis (CA) and linear discriminant analysis (LDA) was applied to differentiate the berries samples according to their type.
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...

