Primary vs secondary adrenal insufficiency: ACTH-stimulated aldosterone diagnostic cut-off values by tandem mass spectrometry
Related Experiment Video
Updated: Apr 18, 2026

A Novel Method: Super-selective Adrenal Venous Sampling
Published on: September 15, 2017
Smita Baid Abraham1, Brent S Abel1, Ninet Sinaii2
1The Program in Reproductive and Adult Endocrinology, The Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, Bethesda, MD, USA.
Objectives:
To validate the diagnostic utility of Cortrosyn(™) stimulated aldosterone in the differentiation of primary (PAI) and secondary adrenal insufficiency (SAI) and to evaluate the effect of urine sodium levels and posture on test performance.
Design:
Cross-sectional study.
Methods:
Healthy volunteers (HV; n = 46) and patients with PAI (n = 26) and SAI (n = 29) participated in the study. Testing included cortisol and aldosterone (by liquid-chromatography tandem mass spectrometry) measurements at baseline and 30 and 60 min after 250 microg Cortrosyn(™). Plasma corticotropin (ACTH), renin activity (PRA) and urine spot sodium as a proxy for 24-h urine sodium excretion were measured at baseline. The effect of a sitting or semifowlers posture was evaluated in healthy volunteers.
Results:
A Cortrosyn(™)-stimulated aldosterone level of 5 ng/dl (0·14 nmol/l) had 88% sensitivity and positive predictive value and 89·7% specificity and negative predictive value for distinguishing PAI from SAI. Spot urine sodium levels showed a strong correlation with peak aldosterone levels (r = -0·55, P = 0·02, n = 18) in the SAI but not PAI or HV groups. Posture did not have a significant effect on results.
Conclusions:
Once diagnosed with adrenal insufficiency, a stimulated aldosterone value of 5 ng/dl (0·14 nmol/l) works well to differentiate PAI from SAI. However, clinicians should be aware of the possible effect of total body sodium as reflected by spot urine sodium levels on aldosterone results. A 24-h urine sodium measurement may be helpful in interpretation.
Related Concept Videos
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...

