Test-retest variability of adenosine A2A binding in the human brain with (11)C-TMSX and PET
Mika Naganawa1, Masahiro Mishina2, Muneyuki Sakata3
1PET Center, Yale University School of Medicine, 801 Howard Avenue, PO Box 208048, New Haven, CT 06520-8048 USA ; Research Team for Neuroimaging, Tokyo Metropolitan Institute of Gerontology, Tokyo, 173-0015 Japan.
Background:
The goal of the present study was to evaluate the reproducibility of cerebral adenosine A2A receptor (A2AR) quantification using (11)C-TMSX and PET in a test-retest study.
Methods:
Five healthy volunteers were studied twice. The test-retest variability was assessed for distribution volume (V T) and binding potential relative to non-displaceable uptake (BPND) based on either metabolite-corrected arterial blood sampling or a reference region. The cerebral cortex and centrum semiovale were used as candidate reference regions.
Results:
Test-retest variability of V T was good in all regions (6% to 13%). In the putamen, BPND using the centrum semiovale displayed a lower test-retest variability (3%) than that of BPND using the cerebral cortex as a reference region (5%). The noninvasive method showed a higher or similar level of test-retest reproducibility compared to the invasive method.
Conclusions:
Binding reproducibility is sufficient to use (11)C-TMSX as a tool to measure the change in A2AR in the human brain.
More Related Videos
07:28Studying Metabolic Brain Connectivity Using 2-Deoxy-2-[18F]Fluoro-D-Glucose Dynamic Positron Emission Tomography at the Single-subject Level
Published on: January 24, 2025
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...