The qualitative detection of decreases in cardiac output
Michael J Harrison1, Ross Scott-Weekly2, Mathew Zacharias3
1Department of Surgery and Anaesthesia, University of Otago Medical School (Wellington), 23A Mein St. 6021, Wellington, New Zealand.
Background:
Cardiac output is a major factor in the maintenance of physiological homeostasis and is difficult to measure with accuracy. This study describes an evidence-based technique, based on physiological changes, which may indicate small changes in cardiac output that cannot be measured by current techniques.
Method:
Synchronous changes in blood pressure, heart rate, pulse amplitude and end-tidal carbon dioxide are analysed using runs analysis and a normalisation technique. An evidence-based algorithm was used to detect possible changes in cardiac output and data extracts from 31 consenting patients are presented as examples.
Results:
The decrease in end-tidal carbon dioxide, during steady state ventilation, was greater in those events notified as hypovolaemia associated with a fall in cardiac output than those events notified as hypovolaemia alone. The difference in end-tidal carbon dioxide between the two groups was -0.25 kPa (CI -0.42 to -0.09) p<0.003.
Discussion:
Runs analysis can detect trends in EtCO2 that during steady state ventilation may indicate a decrease in cardiac output. It is a safe technique; no additional hardware is required and the generated alerts only notify the clinician of the possibility of an adverse change. Determination of the rate of clinically significant false positives and negatives requires further work.
More Related Videos
Related Concept Videos
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...