Related Experiment Video
Updated: Apr 18, 2026

An In vitro System to Gauge the Thrombolytic Efficacy of Histotripsy and a Lytic Drug
Published on: June 4, 2021
Real-time feedback of histotripsy thrombolysis using bubble-induced color Doppler
Xi Zhang1, Ryan M Miller1, Kuang-Wei Lin1
1Department of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
Abstract:
Histotripsy thrombolysis is a non-invasive, drug-free, image-guided therapy that fractionates blood clots using well-controlled acoustic cavitation alone. Real-time quantitative feedback is highly desired during histotripsy thrombolysis treatment to monitor the progress of clot fractionation. Bubble-induced color Doppler (BCD) monitors the motion after cavitation generated by each histotripsy pulse, which has been found in gel and ex vivo liver tissue to be correlated with histotripsy fractionation. We investigated the potential of BCD to quantitatively monitor histotripsy thrombolysis in real time. To visualize clot fractionation, transparent three-layered fibrin clots were developed. Results indicated that a coherent motion follows the cavitation generated by each histotripsy pulse with a push and rebound pattern. The temporal profile of this motion expands and saturates as treatment progresses. A strong correlation exists between the degree of histotripsy clot fractionation and two metrics extracted from BCD: time of peak rebound velocity (tPRV) and focal mean velocity at a fixed delay (Vf,delay). The saturation of clot fractionation (i.e., treatment completion) matches well the saturations detected using tPRV and Vf,delay. The mean Pearson correlation coefficients between the progression of clot fractionation and the two BCD metrics were 93.1% and 92.6%, respectively. To validate BCD feedback in in vitro clots, debris volumes from histotripsy thrombolysis were obtained at different therapy doses and compared with Vf,delay. There is also good agreement between the increasing and saturation trends of debris volume and Vf,delay. Finally, a real-time BCD feedback algorithm to predict complete clot fractionation during histotripsy thrombolysis was developed and tested. This work illustrates the potential of BCD to monitor histotripsy thrombolysis treatment in real time.
Related Concept Videos
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Venous Thrombosis III: Interprofessional Care

