Related Experiment Video
Updated: Apr 18, 2026

Assessment of Bone Fracture Healing Using Micro-Computed Tomography
Published on: December 9, 2022
Comparison of conventional radiography and MDCT in suspected scaphoid fractures
Cyrus Behzadi1, Murat Karul1, Frank Oliver Henes1
1Cyrus Behzadi, Murat Karul, Frank Oliver Henes, Azien Laqmani, Gerhard Adam, Marc Regier, Center for Radiology and Endoscopy, Department of Diagnostic and Interventional Radiology, University Medical Center Hamburg-Eppendorf, 20246 Hamburg, Germany.
Aim:
To determine the diagnostic accuracy and radiation dose of conventional radiography and multidetector computed tomography (MDCT) in suspected scaphoid fractures.
Methods:
One hundred twenty-four consecutive patients were enrolled in our study who had suffered from a wrist trauma and showed typical clinical symptoms suspicious of an acute scaphoid fracture. All patients had initially undergone conventional radiography. Subsequent MDCT was performed within 10 d because of persisting clinical symptoms. Using the MDCT data as the reference standard, a fourfold table was used to classify the test results. The effective dose and impaired energy were assessed in order to compare the radiation burden of the two techniques. The Wilcoxon test was performed to compare the two diagnostic modalities.
Results:
Conventional radiography showed 34 acute fractures of the scaphoid in 124 patients (42.2%). Subsequent MDCT revealed a total of 42 scaphoid fractures. The sensitivity of conventional radiography for scaphoid fracture detection was 42.8% and its specificity was 80% resulting in an overall accuracy of 59.6%. Conventional radiography was significantly inferior to MDCT (P < 0.01) concerning scaphoid fracture detection. The mean effective dose of MDCT was 0.1 mSv compared to 0.002 mSv of conventional radiography.
Conclusion:
Conventional radiography is insufficient for accurate scaphoid fracture detection. Regarding the almost negligible effective dose, MDCT should serve as the first imaging modality in wrist trauma.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation I: X-ray and CT

