Related Experiment Video
Updated: Apr 18, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
EFFECTS OF TWO CONTRAST INJECTION PROTOCOLS ON FELINE AORTIC AND HEPATIC ENHANCEMENT USING DYNAMIC COMPUTED
Mariano Makara1, Jennifer Chau1, Evelyn Hall1
1Faculty of Veterinary Science, University of Sydney, NSW, 2006, Sydney, Australia.
Abstract:
This prospective study compared aortic and hepatic enhancement achieved using a contrast injection protocol with a fixed rate of 5 ml/s vs. that achieved using a protocol with fixed injection duration of 20 s in eight cats. Cats were assigned into two groups (Group 1, rate 5 ml/s; Group 2, duration 20 s). The dose of contrast was the same in both groups (740 mgI/kg). Regions of interest (ROI) were drawn in the aorta and liver for transverse scans acquired at the hepatic hilus. Time to peak aortic enhancement occurred significantly earlier in Group 1 (M = 11s, SD = 1.63) than in Group 2 (M = 25.5 s, SD = 2.51). Peak aortic enhancement was significantly higher in Group 1 (M = 1906.51 HU, SD = 368.64) than in Group 2 (M = 745.08 HU, SD = 201.84). Duration of aortic enhancement equal to or above 300 HU was statistically longer in Group 2 (M = 24.5 s, SD = 8.39) than in Group 1 (M = 10 s, SD = 1.63). There were no significant differences in time to peak liver enhancement, peak liver enhancement, or duration of hepatic arterial phase between groups. Findings supported the hypothesis that longer injection duration results in a broader bolus geometry with a longer time to peak and a lower peak aortic enhancement in cat. This strong influence of injection duration on timing of aortic enhancement may help future users optimize protocols for CT angiography of the aorta and multiphasic evaluation of the liver, pancreas, and small intestine.
More Related Videos
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies VII: Vascular Imaging
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...