Capable of more: some underemphasized aspects of capacity assessment

Nicholas Kontos1, John Querques2, Oliver Freudenreich2

  • 1Department of Psychiatry, Massachusetts General Hospital and Harvard Medical School, Boston, MA..

Psychosomatics
|February 5, 2015
PubMed
Abstract

Related Concept Videos

Design Example: Analyzing Capacity Contours for Flood Risk Assessment01:17

Design Example: Analyzing Capacity Contours for Flood Risk Assessment

Flood risk assessment involves careful planning and analysis to ensure the safety of communities near water retention structures. Capacity contours are a vital tool in this process, as they illustrate the potential spread of water at specific levels in a given area. In the context of building a bund across a small valley, these contours play a critical role in evaluating the safety of nearby residential areas.In this example, the bund is intended to store stormwater in the valley. The engineers...
384
Respiratory Capacities01:24

Respiratory Capacities

Respiratory capacities are crucial indicators of lung function, representing the maximum amount of air an individual's respiratory system can handle during various breathing phases.
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
1.7K
Buffers: Buffer Capacity01:09

Buffers: Buffer Capacity

Buffer capacity is the quantitative measure of a buffer to resist the change in pH. As shown in the following equation, the buffer capacity, denoted by 'beta', is expressed as the number of moles of acid or base needed to change the pH of a one-liter buffer solution by 1 unit. Here, Ca and Cb indicate the number of moles of acid and base, respectively. Note that dpH represents the change in pH.
In the graph, pH is plotted as a function of the number of moles of base (Cb) added to a weak...
3.6K
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
732
Load-frequency control01:28

Load-frequency control

Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
821
Compacting Factor test01:22

Compacting Factor test

The compacting factor test is a method used to assess the workability of concrete. It is  especially suitable for concrete mixes containing aggregates up to one and a half inches in size. This test involves specialized equipment consisting of two truncated cone-shaped hoppers and a cylinder, all with polished interior surfaces to minimize friction.
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
733