Related Experiment Video
Updated: Apr 17, 2026

Confocal Time Lapse Imaging as an Efficient Method for the Cytocompatibility Evaluation of Dental Composites
Published on: November 9, 2014
Histological validation of cone-beam computed tomography versus laser fluorescence and conventional diagnostic
11 Department of Restorative Dentistry, Faculty of Dentistry, Hacettepe University , Ankara, Turkey .
Objective:
The purpose of this study was to compare the validity of visual (VE), radiological (RE), cone beam computed tomography (CBCT), and laser fluorescence (LFE) examination methods for the detection of the occlusal noncavitated caries in permanent posterior teeth.
Methods:
Two examiners assessed 121 selected sites on the occlusal surfaces of 44 molar teeth by visual (International Caries Assessment and Detection System II [ICDAS]), radiographic (bite-wing projection) cone-beam computed tomography, and laser fluorescence (DIAGNOdent Pen) examination methods. After a 1-week interval, each measurement was repeated by two examiners. Then, the teeth were sectioned, and histological evaluation was performed, which serves as the gold standard. The lesion depths were classified and correlated with the methods evaluated for validation. The intra- and inter-examiner reliability (sensitivity, specificity) and reproducibility of all examination methods were calculated using a weighted Cohen's κ statistic. The correlation between the examination methods was determined using receiver operating characteristic (ROC) analysis indicating the area under the curve (AUC).
Results:
CBCT exhibited excellent intra-examiner (0.76 for examiner 1, 0.78 for examiner 2) and fair to good inter-examiner (0.63 for the first, 0.64 for the second measurements) reproducibility. The intra-examiner reproducibility was excellent for the LFE method according to the weighted κ values of examiners 1 (0.90) and 2 (0.79). Among the combined methods, the highest AUC values (0.81-0.95) were obtained for the CBCT examination method performed by the two examiners at both the first and second measurements.
Conclusions:
Cone beam computed tomography showed better performance than other diagnostic methods.
More Related Videos
05:42Detection and Removal of Tooth-Colored Composite Resin Using the Fluorescence-Aided Identification Technique
Published on: July 27, 2022
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Confocal Fluorescence Microscopy
Three-Dimensional Microscopy in Microbiology