Related Experiment Video
Updated: Oct 12, 2026

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
Published on: July 2, 2021
Lack of early dislocation following total hip arthroplasty with a new dual mobility acetabular design
Jonathan M Vigdorchik1, Michele R D'Apuzzo, David C Markel
11 Hospital for Special Surgery, New York - USA.
Abstract:
Dual mobility implant designs minimise the risk of dislocation without sacrificing range of motion. Between 1st September 2008 and 31st July 2011, 5 institutions examined early clinical outcomes of a new dual mobility bearing hip system implanted in 485 primary THAs in 452 patients. Patient demographics were 46% female, a mean age of 67 years and a mean BMI of 30. Complications at a minimum of 2 years after surgery included 1 femur fracture, 1 DVT and 4 unrelated deaths. There were no dislocations. For functional outcomes, Harris Hip Scores increased from 41 to 86 (p<0.001), while VAS pain scores decreased from 5.9 to 0.7 (p<0.001). Minimal complications, excellent early clinical outcomes and the absence of early dislocations demonstrate the improved stability of this dual mobility implant system.