Computed Tomography01:10

Computed Tomography

9.7K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.7K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

How to Take Good Care of Your Radiology Department Chair and Why.

Journal of computer assisted tomography·2023
Same author

Diagnostic yield, safety, and outcomes of Head-to-pelvis sudden death CT imaging in post arrest care: The CT FIRST cohort study.

Resuscitation·2023
Same author

The seven day itch: A delayed histamine reaction to stingray injury.

The American journal of emergency medicine·2023
Same author

Detectability of Small Low-Attenuation Lesions With Deep Learning CT Image Reconstruction: A 24-Reader Phantom Study.

AJR. American journal of roentgenology·2022
Same author

Choosing Wisely.

The Journal of emergency medicine·2022
Same author

CT perfusion as a potential biomarker for pancreatic ductal adenocarcinoma during routine staging and restaging.

Abdominal radiology (New York)·2022
Same journal

Rocuronium dosing for rapid sequence intubation: A retrospective analysis in ED and ICU settings.

The American journal of emergency medicine·2026
Same journal

Clinical features of adults with undiagnosed acute leukemia in the emergency department: A descriptive study.

The American journal of emergency medicine·2026
Same journal

Occult intraperitoneal gynecological hemorrhage: An under-evaluated source of hemoperitoneum after blunt trauma.

The American journal of emergency medicine·2026
Same journal

Racket and paddle sports-related injuries treated in United States emergency departments, 2000-2023.

The American journal of emergency medicine·2026
Same journal

Prehospital epinephrine as a bridge to survival in traumatic cardiac arrest: A nationwide propensity score-matched analysis.

The American journal of emergency medicine·2026
Same journal

Crowdsourcing technologies for out-of-hospital cardiac arrest response: A scoping review.

The American journal of emergency medicine·2026
See all related articles

Related Experiment Video

Updated: Apr 17, 2026

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
07:57

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform

Published on: March 24, 2022

3.4K

The use of model-based iterative reconstruction to decrease ED radiation exposure.

Medley O Gatewood1, Lindsay Grubish2, Janet M Busey3

  • 1Division of Emergency Medicine, University of Washington School of Medicine, Seattle, WA, USA.

The American Journal of Emergency Medicine
|February 10, 2015
PubMed
Summary
This summary is machine-generated.

This study evaluated whether a new image processing technology, model-based iterative reconstruction, could lower radiation doses for patients undergoing CT scans in the emergency department without significantly increasing the time patients spend in the hospital.

Keywords:
radiation dose reductionemergency department throughputimaging protocol optimizationclinical workflow efficiency

Frequently Asked Questions

More Related Videos

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
08:17

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy

Published on: June 7, 2015

16.3K
Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures
09:10

Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures

Published on: August 5, 2021

2.4K

Related Experiment Videos

Last Updated: Apr 17, 2026

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
07:57

Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform

Published on: March 24, 2022

3.4K
Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy
08:17

Dynamic Lung Tumor Tracking for Stereotactic Ablative Body Radiation Therapy

Published on: June 7, 2015

16.3K
Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures
09:10

Digital Hybrid Model Preparation for Virtual Planning of Reconstructive Dentoalveolar Surgical Procedures

Published on: August 5, 2021

2.4K

Area of Science:

  • Diagnostic radiology within model-based iterative reconstruction research
  • Emergency medicine clinical outcomes

Background:

Diagnostic imaging techniques often carry inherent risks related to ionizing radiation exposure. Clinicians frequently struggle to balance image quality with patient safety during routine examinations. No prior work had resolved the trade-off between advanced reconstruction algorithms and clinical workflow efficiency. That uncertainty drove the need for a comprehensive assessment of departmental throughput. Prior research has shown that standard protocols often result in higher radiation doses than necessary for diagnostic accuracy. This gap motivated an investigation into modern computational approaches. Many medical centers remain hesitant to adopt new technologies due to concerns regarding potential delays in patient care. The current landscape demands evidence-based strategies to optimize both safety and operational speed.

Purpose Of The Study:

The aim of this investigation was to evaluate the clinical impact of advanced image reconstruction technology. Researchers sought to determine if this method could effectively lower radiation exposure for patients. A secondary objective involved assessing whether the technology altered the duration of emergency department visits. The study addressed the concern that advanced processing might slow down patient care. By comparing new protocols to standard methods, the team quantified the trade-offs between safety and speed. This work was motivated by the need to optimize diagnostic imaging in high-volume settings. No prior work had resolved the potential conflict between reduced-dose imaging and departmental efficiency. The authors intended to provide evidence to guide clinical adoption of these safer imaging practices.

Main Methods:

The investigators conducted a retrospective, matched, case-control analysis to evaluate clinical performance. They identified 121 patients meeting specific inclusion criteria for the low-dose imaging group. These individuals were paired with an equal number of controls to reach a total sample size of 242. The review approach focused on two primary variables: total duration of stay and radiation dose metrics. Researchers extracted data from electronic health records to compare the two distinct imaging protocols. Statistical testing determined the significance of differences between the cohorts. This design ensured that patient characteristics remained balanced across both study arms. The team utilized standard statistical software to calculate p-values and mean differences for all primary outcomes.

Main Results:

Key findings from the literature demonstrate a 34% reduction in radiation dose for the low-dose group. The mean volume CT dose index measured 7.7 mGy compared to 11.6 mGy for standard protocols. This difference reached statistical significance with a p-value below 0.001. Regarding operational efficiency, the overall mean length of stay was 520 minutes for the low-dose group. Controls experienced a mean stay of 502 minutes, resulting in an 18-minute difference. Admitted patients showed a mean stay of 587 minutes versus 576 minutes for the standard group. Discharged patients had a mean stay of 490 minutes compared to 468 minutes for the controls. Statistical analysis confirmed that these variations in time were not significant.

Conclusions:

The authors propose that this advanced reconstruction technique effectively lowers radiation doses for patients. Synthesis and implications suggest that clinical workflows remain largely unaffected by the adoption of these protocols. The data indicate a substantial reduction in ionizing radiation without compromising the speed of emergency care. These findings support the integration of such technology into standard diagnostic practices. The researchers emphasize that the observed differences in patient throughput were not statistically significant. This evidence provides a pathway for departments to prioritize safety without sacrificing operational efficiency. The study highlights the feasibility of implementing low-dose protocols in high-acuity settings. Future efforts should continue to monitor the balance between technological advancements and patient care timelines.

The researchers propose that the technology achieves a 34% reduction in radiation dose. This is measured by the volume CT dose index, which dropped from 11.6 mGy in standard protocols to 7.7 mGy in the low-dose group.

The study utilized model-based iterative reconstruction, a computational method designed to enhance image quality from lower radiation inputs. This approach contrasts with standard reconstruction protocols that typically require higher energy levels to achieve comparable diagnostic clarity.

The authors note that the processing time is a potential drawback of this technology. However, the study confirms that the overall length of stay in the emergency department showed no significant statistical difference between the two groups.

The researchers employed a retrospective, matched, case-control design to evaluate 242 total subjects. This data structure allows for a direct comparison between patients receiving the new protocol and those undergoing standard imaging procedures.

The study measured the mean length of stay in minutes for both admitted and discharged patients. The results showed an 18-minute difference overall, which the authors determined was not statistically significant based on the p-value of 0.497.