Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

9.7K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.7K
Curvilinear Motion: Rectangular Components01:23

Curvilinear Motion: Rectangular Components

1.6K
Curvilinear motion characterizes the movement of a particle or object along a curved path, notably evident when envisioning a car navigating a winding road. If the car starts at point A, its position vector is established within a fixed frame of reference, where the ratio of the position vector to its magnitude signifies the unit vector pointing in the position vector's direction.
As the car advances, its position evolves over time. Quantifying the car's velocity involves computing the...
1.6K
Relative Motion Analysis using Rotating Axes01:25

Relative Motion Analysis using Rotating Axes

1.1K
Consider a component AB undergoing a linear motion. Along with a linear motion, point B also rotates around point A. To comprehend this complex movement, position vectors for both points A and B are established using a stationary reference frame.
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
1.1K
Relative Motion Analysis using Rotating Axes-Problem Solving01:29

Relative Motion Analysis using Rotating Axes-Problem Solving

862
Consider a crane whose telescopic boom rotates with an angular velocity of 0.04 rad/s and angular acceleration of 0.02 rad/s2. Along with the rotation, the boom also extends linearly with a uniform speed of 5 m/s. The extension of the boom is measured at point D, which is measured with respect to the fixed point C on the other end of the boom. For the given instant, the distance between points C and D is 60 meters.
Here, in order to determine the magnitude of velocity and acceleration for point...
862
Imaging Studies III: Computed Tomography01:27

Imaging Studies III: Computed Tomography

816
DefinitionComputed Tomography (CT) of the genitourinary (GU) tract is a non-invasive imaging modality that utilizes X-rays and computer processing to generate detailed cross-sectional images of the urinary system, encompassing the kidneys, ureters, bladder, and adjacent structures such as the adrenal glands.PurposeCT scans of the GU tract serve several diagnostic and therapeutic purposes, including:Diagnosis of Urinary Tract Diseases: Detects kidney stones, tumors, cysts, and congenital...
816
Rotational Motion about a Fixed Axis01:26

Rotational Motion about a Fixed Axis

1.9K
A rigid body's rotation around a fixed axis makes every point within it trace a circular path around a specific line or point. The term given to this type of spinning is defined by the angular position, symbolized by the angle θ. This angle is gauged from a static reference line to the revolving object. From this angular position, any variation is referred to as angular displacement, denoted by dθ. The extent of this displacement can be calculated in degrees, radians, or...
1.9K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

National and regional trends in the prevalence of adolescent idiopathic scoliosis in South Korean military draftees.

BMJ military health·2024
Same author

Acceleration of HDL-Mediated Cholesterol Efflux Alleviates Periodontitis.

Journal of dental research·2024
Same author

The verification of the utility of a commercially available phantom combination for quality control in contrast-enhanced mammography.

Physical and engineering sciences in medicine·2024
Same author

Effect of postbiotic Lactiplantibacillus plantarum LRCC5314 supplemented in powdered milk on type 2 diabetes in mice.

Journal of dairy science·2024
Same author

Author Correction: Fabrication of THz corrugated wakefield structure and its high power test.

Scientific reports·2023
Same author

Fabrication of THz corrugated wakefield structure and its high power test.

Scientific reports·2023
Same journal

Deep learning-based dose prediction to enhance planning efficiency in cervical brachytherapy with hybrid applicators.

Physics in medicine and biology·2026
Same journal

Corrigendum: Referenceless MR thermometry-a comparison of five methods (2017<i>Phys. Med. Biol</i>.<b>62</b>1-16).

Physics in medicine and biology·2026
Same journal

Corrigendum: Measured and Monte Carlo simulated electron backscatter to the monitor chamber for the varian TrueBeam linac (2016<i>Phys. Med. Biol</i>.<b>61</b>8779).

Physics in medicine and biology·2026
Same journal

Corrigendum: 3D range-modulator for scanned particle therapy: development, Monte Carlo simulations and experimental evaluation (2017<i>Phys. Med. Biol</i>.<b>62</b>7075).

Physics in medicine and biology·2026
Same journal

Recent progress in applications of computing to radiotherapy (ICCR 2016).

Physics in medicine and biology·2026
Same journal

Novel TMS coils designed using an inverse boundary element method.

Physics in medicine and biology·2026
See all related articles

Related Experiment Video

Updated: Apr 17, 2026

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
05:05

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

Published on: November 23, 2019

8.6K

A rigid motion correction method for helical computed tomography (CT).

J-H Kim1, J Nuyts, A Kyme

  • 1Discipline of Medical Imaging and Sciences, University of Sydney, NSW 2006, Australia.

Physics in Medicine and Biology
|February 13, 2015
PubMed
Summary
This summary is machine-generated.

This study introduces a novel method for correcting six-degree-of-freedom rigid motion in helical CT scans of the head. The technique significantly improves image quality, reducing the need for repeat scans in motion-prone patients.

More Related Videos

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
07:43

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy

Published on: July 2, 2021

3.8K
Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
06:09

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography

Published on: March 12, 2021

4.0K

Related Experiment Videos

Last Updated: Apr 17, 2026

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
05:05

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration

Published on: November 23, 2019

8.6K
In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy
07:43

In Vivo Quantification of Hip Arthrokinematics during Dynamic Weight-bearing Activities using Dual Fluoroscopy

Published on: July 2, 2021

3.8K
Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography
06:09

Measuring 3D In-vivo Shoulder Kinematics using Biplanar Videoradiography

Published on: March 12, 2021

4.0K

Area of Science:

  • Medical Imaging
  • Computed Tomography
  • Image Reconstruction

Background:

  • Helical CT (computed tomography) is crucial for head imaging, but patient motion degrades image quality.
  • Six-degree-of-freedom (6-DoF) rigid motion presents a significant challenge in helical CT, particularly for pediatric patients or those requiring sedation.
  • Accurate motion compensation is essential for reliable diagnosis and treatment planning.

Purpose of the Study:

  • To develop and validate a method for compensating six-degree-of-freedom rigid motion in helical CT of the head.
  • To assess the accuracy and robustness of the proposed motion correction technique.
  • To explore the potential clinical applications and benefits of generalized motion correction in CT imaging.

Main Methods:

  • A novel motion compensation method was proposed, utilizing an optical motion tracking system to record head and bed movement.
  • Projection consistency was restored using motion tracking data, followed by reconstruction with an iterative, fully 3D algorithm.
  • The method was evaluated using simulations and helical scans of a brain phantom, with accuracy assessed against stationary reference scans.

Main Results:

  • Motion-corrected helical CT images showed high correlation (coefficients > 0.9) and similarity to stationary reference scans.
  • The method demonstrated effective compensation for realistic human head movements in simulation studies.
  • Optimization of tracker sampling rate, jitter, interpolation, and synchronization further enhanced accuracy.

Conclusions:

  • The developed method provides the first practical demonstration of generalized rigid motion correction for helical CT of the head.
  • This technique has the potential to significantly reduce repeat scans and the need for sedation in motion-prone patient groups.
  • The approach is applicable to dedicated CT, as well as hybrid PET/CT and SPECT/CT systems, improving image accuracy for localization and attenuation correction.