Isothermal titration calorimetry of ion-coupled membrane transporters

Olga Boudker1, SeCheol Oh1

  • 1Department of Physiology & Biophysics, Weill Cornell Medical College, New York 10021, USA.

Methods (San Diego, Calif.)
|February 14, 2015
PubMed

Related Concept Videos

Transport Number01:31

Transport Number

The transport number is the fraction of the total current carried by an ion in an electrolyte solution. It is defined as the ratio of the current carried by a specific ion to the total current flowing through the solution. The transport number, t, is central to understanding ionic mobility, which describes how fast an ion moves under the influence of an electric field. This link connects the physical behavior of ions in solution to the chemical processes that occur during electrochemical...
192
The Significance of Membrane Transport01:44

The Significance of Membrane Transport

The transport of solutes across the cell membrane is essential for metabolic processes, like maintaining cell size and volume, generating the action potential, exchanging nutrients and gases, etc. Membrane transport can be either passive or active. It can be simple diffusion, facilitated, or mediated transport aided by transport proteins such as transporters and channels.
Transporters facilitate either an active or passive movement of solutes. They can allow a single-molecule transport down its...
45.1K
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
2.4K
Constant Pressure Calorimetry03:02

Constant Pressure Calorimetry

Calorimetry is a technique used to measure the amount of heat involved in a chemical or physical process or to measure the heat transferred to or from a substance. The heat is exchanged with a calibrated and insulated device called the calorimeter. Calorimetry experiments are based on the assumption that there is no heat exchange between the insulated calorimeter and the external environment. The well-insulated calorimeters prevent the transfer of heat between the calorimeter and its external...
102.7K
Ion-Exchange Chromatography01:09

Ion-Exchange Chromatography

Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
3.1K
Pore Transport and Ion-Pair Transport01:17

Pore Transport and Ion-Pair Transport

Pore transport and ion-pair formation are critical mechanisms for the absorption and distribution of drugs in the body.
Pore transport, also known as convective transport, is a process where small molecules like urea, water, and sugars rapidly cross cell membranes as though there were channels or pores in the membrane. Although direct microscopic evidence is limited  but the concept of pores or channels is widely accepted based on physiological evidence. Despite the lack of direct...
1.6K