Superior capacitive performance of hydrochar-based porous carbons in aqueous electrolytes

Antonio B Fuertes1, Marta Sevilla

  • 1Instituto Nacional del Carbón (CSIC), P.O. Box 73, Oviedo 33080 (Spain).

Chemsuschem
|February 14, 2015
PubMed

Related Concept Videos

Theory of Strong Electrolytes01:23

Theory of Strong Electrolytes

The interionic forces of the strong electrolytes depend on the solvent's dielectric constant, which is the ability of a solvent to store electrical energy, based on its polarizability. and the solution's concentration. In high-dielectric solvents and in dilute solutions, weak electrostatic forces keep ions apart. However, in low-dielectric solvents or concentrated solutions, stronger interionic forces may cause ions to pair up as ionic doublets despite being fully ionized. The theory of strong...
114
Electrolyte and Nonelectrolyte Solutions02:21

Electrolyte and Nonelectrolyte Solutions

Substances that undergo either a physical or a chemical change in solution to yield ions that can conduct electricity are called electrolytes. If a substance yields ions in solution, that is, if the compound undergoes 100% dissociation, then the substance is a strong electrolyte. Complete dissociation is indicated by a single forward arrow. For example, water-soluble ionic compounds like sodium chloride dissociate into sodium cations and chloride anions in aqueous solution.
75.2K
Potentiometry: Membrane Electrodes01:15

Potentiometry: Membrane Electrodes

Membrane electrodes, also known as p-ion electrodes, use membranes that selectively interact with free analyte ions, generating a potential difference across the membrane. The resulting membrane potential, known as the asymmetry potential, is not zero even when analyte concentrations on both sides of the membrane are equal. The membrane's response is typically not selective to a single analyte but proportional to the concentration of all ions in the sample solution capable of interacting at...
2.4K
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
892
Potentiometry: Types of Electrodes01:19

Potentiometry: Types of Electrodes

Reference electrodes serve as a stable reference point for potentiometric measurements, while indicator and working electrodes react to variations in the composition of a solution.
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
2.7K
Ion Exchange01:17

Ion Exchange

Ion exchange chromatography separates charged molecules from a solution by reversibly exchanging them with mobile, or 'active', ions associated with the oppositely charged stationary phase. This method can be used to separate ions, soften and deionize water, and purify solutions. The polymers comprising the ion-exchange column are high-molecular-weight and chemically stable polymers, crosslinked to be porous and essentially insoluble. They are also functionalized with either acidic or...
1.6K