Related Experiment Video
Updated: Apr 17, 2026

Oral Biofilm Formation on Different Materials for Dental Implants
Published on: June 24, 2018
Alumina reinforced zirconia implants: 1-year results from a prospective cohort investigation
Benedikt Christopher Spies1, Markus Sperlich2, Jonathan Fleiner3
1Center for Dental Medicine, Department of Prosthetic Dentistry, Albert-Ludwigs-University, Freiburg, Germany.
Objective:
The objective of this investigation was to determine the clinical and radiographic outcome of a one-piece alumina-toughened zirconia (ATZ) oral implant for single tooth replacement after 1 year.
Materials And Methods:
A total of 27 patients received one ATZ implant each in a one-stage implant surgery with immediate temporization. Standardized radiographs were taken at implant insertion and after 1 year to monitor peri-implant bone loss. Several soft tissue parameters were evaluated at prosthesis insertion and at the 1-year follow-up.
Results:
Three patients did not receive a prosthetic reconstruction due to implant loss during the healing period. As a result, 24 patients were seen at the 1-year follow-up, giving a cumulative survival rate of 88.9%. The average marginal bone loss after 1 year was 0.77 mm. Only two implants (8.3%) lost at least 2 mm bone, whereas none of the implants lost more than 3 mm. Probing depth and clinical attachment level increased over 1 year at the implant sites, whereas gingival recession remained stable. Mombelli's bleeding and plaque indices showed no statistically significant change within the first year.
Conclusion:
Owing to a total of 27 inserted implants, three failures within the first 4 months after implant placement carry weight. Therefore, the cumulative survival rate of the presented ceramic implant was slightly below reported survival rates of titanium implants when immediately restored. The recorded radiographic bone loss and peri-implant soft tissue parameters showed promising short-term results. The presented ATZ implant seems to be a candidate for clinical usage.
More Related Videos
05:54Real-Time Dynamic Navigation System for the Precise Quad-Zygomatic Implant Placement in a Patient with a Severely Atrophic Maxilla
Published on: October 18, 2021
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material