Related Experiment Video
Updated: Apr 17, 2026

Harnessing the Bioorthogonal Inverse Electron Demand Diels-Alder Cycloaddition for Pretargeted PET Imaging
Published on: February 3, 2015
Improved metabolic stability for 18F PET probes rapidly constructed via tetrazine trans-cyclooctene ligation
Ramajeyam Selvaraj1, Benjamin Giglio2, Shuanglong Liu3
1†Brown Laboratories, Department of Chemistry and Biochemistry, University of Delaware, Newark, Delaware 19803, United States.
Abstract:
The fast kinetics and bioorthogonal nature of the tetrazine trans-cyclooctene (TCO) ligation makes it a unique tool for PET probe construction. In this study, we report the development of an (18)F-labeling system based on a CF3-substituted diphenyl-s-tetrazine derivative with the aim of maintaining high reactivity while increasing in vivo stability. c(RGDyK) was tagged by a CF3-substituted diphenyl-s-tetrazine derivative via EDC-mediated coupling. The resulting tetrazine-RGD conjugate was combined with a (19)F-labeled TCO derivative to give HPLC standards. The analogous (18)F-labeled TCO derivative was combined with the diphenyl-s-tetrazine-RGD at μM concentration. The resulting tracer was subjected to in vivo metabolic stability assessment, and microPET studies in murine U87MG xenograft models. The diphenyl-s-tetrazine-RGD combines with an (18)F-labeled TCO in high yields (>97% decay-corrected on the basis of TCO) using only 4 equiv of tetrazine-RGD relative to the (18)F-labeled TCO (concentration calculated based on product's specific activity). The radiochemical purity of the (18)F-RGD peptides was >95% and the specific activity was 111 GBq/μmol. Noninvasive microPET experiments demonstrated that (18)F-RGD had integrin-specific tumor uptake in subcutaneous U87MG glioma. In vivo metabolic stability of (18)F-RGD in blood, urine, and major organs showed two major peaks: one corresponded to the Diels-Alder conjugate and the other was identified as the aromatized analog. A CF3-substituted diphenyl-s-tetrazine displays excellent speed and efficiency in (18)F-PET probe construction, providing nearly quantitative (18)F labeling within minutes at low micromolar concentrations. The resulting conjugates display improved in vivo metabolic stability relative to our previously described system.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET

