In vitro mechanical analysis of complete-arch mandibular implant-supported fixed prostheses abutment screws after
Andreina Sananez1, Carol Lefebvre2, Stephen Looney3
1Assistant Professor, Department of Oral Rehabilitation, Georgia Regents University, College of Dental Medicine, Augusta, Ga.
Statement Of Problem:
Clinicians question when to evaluate for worn or loose implant-supported retainer screws to prevent possible clinical complications.
Purpose:
The purpose of this study was to compare differences among initial and postdynamically loaded detorque values and identify physical structural changes of prosthetic retaining screws in a simulated implant-supported mandibular complete fixed prosthesis.
Material And Methods:
Nine groups and nonloaded controls comprising a 5-implant-supported, milled titanium framework were fabricated and assembled (screw torque 35 Ncm). Dynamic loading (20 to 220 N) was applied to simulate 2 years of oral function. After testing, screw detorque values were measured (ΔT, initial-detorque value). A scanning electron microscopic analysis of screw threads was used to assess physical changes. Data were analyzed by 2-way ANOVA to determine the influence of loading and implant position on ΔT (α=.05).
Results:
ΔT values of loaded and nonloaded groups were compared separately at each implant position and showed a significant difference only for the implant in the central position (P=.002). All positions were compared in terms of ΔT values separately for loaded and nonloaded conditions. A significantly higher ΔT was found in 1 cantilever area of the loaded group, whereas a significantly lower ΔT value was found in the central position in the nonloaded group. No statistically significant differences were found in physical changes between loading and nonloading or among implant positions.
Conclusions:
When delivering a multiimplant supported prosthesis, the application of dynamic loading and the sequence in which implant screws are tightened could influence the subsequent detorque value of a screw; they have no effect on the physical appearance of screws after extended function.
More Related Videos
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Normal Strain under Axial Loading