Related Experiment Video
Updated: Apr 17, 2026

Proteome-wide Quantification of Labeling Homogeneity at the Single Molecule Level
Published on: April 19, 2019
Comparison of colorimetric methods for the quantification of model proteins in aqueous two-phase systems
Anna Glyk1, Sandra L Heinisch1, Thomas Scheper1
1Institute of Technical Chemistry, Leibniz University of Hannover, 30167 Hannover, Germany.
Abstract:
In the current study, the quantification of different model proteins in the presence of typical aqueous two-phase system components was investigated by using the Bradford and bicinchoninic acid (BCA) assays. Each phase-forming component above 1 and 5 wt% had considerable effects on the protein quantification in both assays, respectively, resulting in diminished protein recoveries/absorption values by increasing poly(ethylene glycol) (PEG)/salt concentration and PEG molecular weight. Therefore, a convenient dilution of both components (up to 1 and 5 wt%) before protein quantification is recommended in both assays, respectively, where the BCA assay is favored in comparison with the Bradford assay.