Related Experiment Video
Updated: Apr 17, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
First experience with the new generation Edwards Sapien 3 aortic bioprosthesis: procedural results and short term
Marie-Isabel Murray1, Nicolas Geis, Sven T Pleger
1Department of Cardiology, Angiology and Pulmology, Heidelberg University Hospital, Heidelberg, Germany.
Background:
TAVR has become an established treatment for severe symptomatic aortic stenosis in patients with high surgical risk. The latest generation of the balloon-expandable Edwards Sapien device, the Sapien 3, together with its new transfemoral Commander delivery system has been designed to reduce paravalvular regurgitation and vascular access site complications.
Objectives:
To evaluate procedural results and short term outcome with the third generation Sapien 3 device.
Methods:
We retrospectively evaluated 125 consecutive TAVR patients and analyzed the first 51 patients in whom we implanted the new Sapien 3 device via transfemoral access.
Results:
In patients implanted with the Sapien 3 device significant residual paravalvular regurgitation after TAVR was virtually absent with the vast majority having none or trace postinterventional aortic regurgitation on angiography or echocardiography (92.2% and 80.4% respectively). None of the patients had more than mild paravalvular regurgitation. Major vascular access site complications or major bleeding according to the VARC II criteria were not observed in our cohort, minor vascular complications and minor bleeding occurred in 7.8% and 5.9% respectively. If vascular complications occurred, they were related to closure device failure. Thirty day outcome showed a 1.9% major stroke rate and 3.9% death rate. However, we observed a 25.5% permanent pacemaker rate in our Sapien 3 cohort.
Conclusions:
Implantation of the new third generation Sapien 3 device resulted in excellent procedural and short term outcome. Significant paravalvular regurgitation was virtually absent. However, the increased rate of postinterventional pacemaker implantations needs to be analyzed in a larger cohort of patients.