Frequency and temperature dependence of skin bioimpedance during a contralateral cold test
S Podtaev1, D Nikolaev, V Samartsev
1Institute of Continuous Media Mechanics, Korolyov str.1, Perm 614013, Russia.
Abstract:
A study of the α- and β-dispersion of skin bioimpedance dependence on temperature and micro-hemodynamics is presented. The vascular tone changes during the cold test are verified by the wavelet-analysis of skin temperature signals obtained simultaneously with impedance measurements. Thirty three normal healthy subjects of 28 ± 7 years old were entered into the study. The tetra-polar electrode system was used to record the resistance and reactance; measurements were carried out at 67 frequencies, in a frequency range from 2 Hz to 50 kHz. It has been found that the impedance decreases with vasodilation and increases with vasoconstriction. The high values of correlation among thermal oscillation amplitudes and Nyquist diagram parameters prove the impedance dependence on blood flow in three frequency bands corresponding to the myogenic, neurogenic and endothelial vascular tone regulation mechanisms. Using an equivalent RC circuit, we obtained the changes in the Nyquist diagram matching the experimental data. The proposed descriptive α-dispersion model can be used to study mechanisms responsible for intercellular interaction.
Related Concept Videos
Thermosensation
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Resistance and Conductance
Various factors impact the resistance of a conductor. Spiraling in stranded conductors increases their...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...