Related Experiment Video
Updated: Apr 17, 2026

Author Spotlight: A Non-Intubated Video-Assisted Thoracoscopic Surgery with Multimodal Analgesia and Sevoflurane Inhalation Anesthesia
Published on: May 26, 2023
Feasibility Study on Neurally Adjusted Ventilatory Assist in Noninvasive Ventilation After Cardiac Surgery in Infants
Laurent Houtekie1, Damien Moerman2, Amaury Bourleau3
1Pediatric Critical Care Unit, Cliniques Universitaires Saint-Luc, Brussels laurent.houtekie@uclouvain.be.
Background:
Our objective was to evaluate the feasibility, the quality of synchronization, and the influence on respiratory parameters of the noninvasive neurally adjusted ventilatory assist (NIV-NAVA) mode in infants after cardiac bypass surgery. We conducted a prospective, randomized cross-over study in infants undergoing noninvasive ventilation (NIV) after cardiac surgery.
Methods:
Subjects were 10 infants < 5 kg. After extubation, subjects underwent 2 consecutive ventilatory modes after randomization into groups. In the CPAP first group, the subjects were ventilated first in nasal CPAP-1 and then in NIV-NAVA-2 for 30 min in each mode. In the NIV-NAVA first group, periods were reversed. All children were ventilated using the same interface.
Results:
The analysis of curves showed a synchronization rate of 99.3% for all respiratory cycles. The rate of pneumatic inspiratory trigger was 3.4%. Asynchronies were infrequent. Some typical respiratory patterns (continuous effort and discontinuous inspiration) were found at rates of 10.9% and 31.1%, respectively. The respiratory trends showed a lower maximum diaphragmatic electrical activity (EAdi(max)) in NIV-NAVA periods compared with CPAP periods (P < .001 in the beginning of periods). The breathing frequency decreased significantly during the nasal CPAP-2 and NIV-NAVA-1 periods (P < .05). The inspiratory pressure increased significantly during the NIV-NAVA-1 and NIV-NAVA-2 periods (P < .05), but there was no significant difference for each parameter when comparing Δ values between the beginning and the end of each period. The EAdi signal was easy to obtain in all subjects, and no major side effects were associated with the use of NIV-NAVA.
Conclusions:
NIV-NAVA allows good synchronization in bi-level NIV in infant cardiac subjects weighing < 5 kg. The analysis of respiratory parameters shows that NIV NAVA decreases the work of breathing more effectively than nasal CPAP. The study shows some typical respiratory patterns in infants. (ClinicalTrials.gov registration NCT01570933.).
More Related Videos
04:16Inspiratory Muscle Training as an Adjunct to the Treatment of Weaning Failure in Critically Ill Patients: A Practical Guide
Published on: January 30, 2026
04:56Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Cardiopulmonary Resuscitation II: ACLS Airway Management