Related Experiment Video
Updated: Apr 17, 2026

Magnetic Resonance Derived Myocardial Strain Assessment Using Feature Tracking
Published on: February 12, 2011
A region-matching method for pulse transit time estimation: potential for improving the accuracy in determining
F S Hu1,2, Y L Zhang2, Z C Ma2
1Department of Automation, University of Science and Technology of China, Hefei, PR China.
Abstract:
Carotid femoral pulse wave velocity (cfPWV) is the 'gold standard' for assessment of arterial stiffness. The reliability of cfPWV measurement depends on the estimation of pulse transit time (PTT). This study aimed to validate a region-matching method for determining PTT and cfPWV against the existing 'foot-to-foot' methods. A cohort of 81 subjects (33 males and 48 females) aged 25-80 (45.1±15.7 years) were studied. PTTs were estimated by the region matching and 'foot-to-foot' methods ('diastole minimum', 'maximum first derivative', 'maximum second derivative' and 'tangent intersection' methods) with manual identification as the reference method and were subsequently used to calculate cfPWV. In a subgroup of 30 individuals, the measurements were repeated after 1 h. There were excellent correlations between cfPWV obtained by the reference method and all the estimated methods (r>0.9, P<0.001 for all), except the diastole minimum method (r=0.793, P<0.001). The region-matching method yielded cfPWV with a better accuracy (mean difference=-0.161 m s(-1), limits of agreement: -0.79 to 0.46 m s(-1)) and repeatability (mean difference=-0.228 m s(-1), intraclass correlation coefficient=0.957) comparing with the 'foot-to-foot' methods. These results demonstrate that the proposed region-matching method is more accurate and suitable for PTT estimation and cfPWV measurement.
More Related Videos
11:04Quantification of Global Diastolic Function by Kinematic Modeling-based Analysis of Transmitral Flow via the Parametrized Diastolic Filling Formalism
Published on: September 1, 2014
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
Related Concept Videos
Special considerations while measuring pulse
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
Rectangular and Triangular Pulse Function
For example, consider a rectangular pulse with a 5V amplitude, a 3-second duration, and centered at t=2 seconds. This pulse can be expressed using the rectangular function, written as,
Noncompartmental Analysis: Mean Residence Time
After the administration of a drug through intravenous bolus injection, the drug molecules are distributed throughout the body and remain there for varying periods. The MRT represents the average time these drug molecules stay in the...
Distance Measurements by Taping
Trapezoidal Rule