Allergic reaction to polysulphone membrane dialyser masquerading as infection
Japheth E Mukaya1, Mitchell S Jacobson1, Don Esprit1
1North Shore Medical Center, Salem, Massachusetts, USA.
Abstract:
Hypersensitivity reactions during haemodialysis are well documented in the literature. Most dialysis membrane reactions occur with ethylene oxide or non-biocompatible membranes and less frequently with biocompatible membranes. The symptoms are non-specific except for the temporal relationship typically occurring during the haemodialysis. Patients who present with the non-classic type of reaction pose a diagnostic challenge and clinicians must have a high index of suspicion. We present a non-classic presentation of a hypersensitivity reaction to a polysulfone membrane dialyser with recurrent fevers during and after haemodialysis, initially thought to be due to infection. After a series of negative work ups for infection, dialysis membrane reaction was considered and the patient improved after change of the membrane.