Assessment of oxygen saturation in retinal vessels of normal subjects and diabetic patients with and without retinopathy using Flow Oximetry System
Mohamed A Ibrahim1, Rachel E Annam1, Yasir J Sepah1
11 Retinal Imaging Research and Reading Center (RIRRC), Wilmer Eye Institute, Johns Hopkins University, School of Medicine, Baltimore, MD, USA ; 2 Ocular Imaging Research and Reading Center (OIRRC), Stanley M. Truhlsen Eye Institute, University of Nebraska Medical Center, Omaha, NE, USA ; 3 Department of Biomedical Engineering, The Catholic University of America, Washington, DC, USA ; 4 Dana Center for Preventive Ophthalmology, Johns Hopkins University, Baltimore, Maryland, USA ; 5 Department of Electrical and Computer Engineering, Portland State University, Oregon, USA ; 6 Department of Biomedical Engineering, and Herbert Wertheim College of Medicine, Florida International University, Miami, FL, USA.
Purpose:
To assess oxygen saturation (StO2) in retinal vessels of normal subjects and diabetic patients with and without retinopathy using the modified version of the Flow Oximetry System (FOS) and a novel assessment software.
Methods:
The FOS and novel assessment software were used to determine StO2 levels in arteries and veins located between 1 and 2 mm from the margin of the optic disc and in the macular area.
Results:
Eighteen normal subjects, 15 diabetics without diabetic retinopathy (DM no DR), and 11 with non-proliferative diabetic retinopathy (NPDR) were included in final analysis. The mean [± standard deviation (SD)] StO2 in retinal arteries was 96.9%±3.8% in normal subjects; 97.4%±3.7% in DM no DR; and 98.4%±2.0% in NPDR. The mean venous StO2 was 57.5%±6.8% in normal subjects; 57.4%±7.5% in DM no DR; and 51.8%±6.8% in NPDR. The mean arterial and venous StO2 across the three groups were not statistically different (P=0.498 and P=0.071, respectively). The arterio-venous differences between the three study groups, however, were found to be statistically significant (P=0.015). Pairwise comparisons have demonstrated significant differences when comparing the A-V difference in the NPDR group to either normal subjects (P=0.02) or diabetic patients without DR (P=0.04).
Conclusions:
The arterio-venous difference was greater, and statistically significant, in patients with NPDR when compared to normal subjects and to patients with diabetes and no retinopathy. The mean venous StO2 was lower, but not statistically significant, in NPDR compared with diabetics without retinopathy and with normal subjects.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...