Related Concept Videos

Raman Spectroscopy: Overview01:20

Raman Spectroscopy: Overview

The underlying principle of Raman spectroscopy is based on the interaction between light and matter, specifically molecules' inelastic scattering of photons. When a monochromatic beam of light, typically from a laser source, interacts with a sample, most scattered light has the same frequency as the incident light. This is known as Rayleigh scattering.
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and...
2.7K
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
1.9K
Therapeutic Drug Monitoring: Drug Analysis Methods01:26

Therapeutic Drug Monitoring: Drug Analysis Methods

Therapeutic Drug Monitoring (TDM) is a clinical practice that measures specific drug levels in a patient's blood or body tissues to tailor drug therapy effectively. This monitoring is critical for managing drugs with narrow therapeutic indices like digoxin and phenytoin, ensuring they are both safe and effective. For instance, monitoring theophylline levels in asthma patients involves precision and sensitivity to adjust doses according to individual responses to therapy, ensuring efficacy and...
323
NMR Spectroscopy of Aromatic Compounds01:14

NMR Spectroscopy of Aromatic Compounds

Aromatic compounds can be identified or analyzed using proton NMR and carbon‐13 NMR. Typically, aromatic hydrogens or hydrogens directly bonded to the aromatic rings are strongly deshielded by the aromatic ring current. Therefore, they absorb in the range of 6.5–8.0 ppm in proton NMR spectra. For instance, aromatic hydrogens directly bonded to the benzene ring absorb at 7.3 ppm. However, aromatic hydrogens of larger rings absorb farther upfield or downfield than the ideal range.
6.8K
Atherosclerosis III: Management01:26

Atherosclerosis III: Management

Management of atherosclerosis involves an integrated strategy encompassing pharmacological treatment, surgical interventions, lifestyle changes, and nutrition therapy to address the multifactorial nature of the disease.Pharmacological TherapyA cornerstone of atherosclerosis management is the use of pharmacological agents. Statins, such as atorvastatin, are pivotal in inhibiting HMG-CoA reductase, an enzyme that catalyzes an initial step in cholesterol synthesis in the liver. This reduction in...
613
Spectroscopy of Carboxylic Acid Derivatives01:26

Spectroscopy of Carboxylic Acid Derivatives

Infrared spectroscopy is primarily used to determine the types of bonds and functional groups. In carboxylic acid derivatives, a typical carbonyl bond absorption is observed around 1650–1850 cm−1. For esters, the absorption is recorded at around 1740 cm−1, while acid halides show the absorption at about 1800 cm−1. Another acid derivative, the acid anhydrides, exhibit two carbonyl absorption around 1760 cm−1 and 1820 cm−1, arising from the symmetrical and...
3.3K