Cardiac mechanics in heart transplant recipients with and without transplant vasculopathy

Elvin Zengin1, Dirk Westermann, Ulf Radunski

  • 1Department of General and Interventional Cardiology, University Heart Center Hamburg, Martinistr. 52, 20246, Hamburg, Germany.

Insights

Cardiac mechanics in heart transplant recipients (HTR) improve post-transplant. Speckle tracking echocardiography assesses function, but coronary angiography remains crucial for diagnosing transplant vasculopathy (TVP).

Area of Science:

  • Cardiology
  • Transplantation Medicine
  • Medical Imaging

Background:

  • Cardiac mechanics evaluation is vital for heart transplant recipients (HTR).
  • Transplant vasculopathy (TVP) is a risk factor for impaired organ function and rejection.
  • Echocardiography-based strain assessment can characterize cardiac function.

Purpose of the Study:

  • To evaluate cardiac mechanics in HTR using 2D speckle tracking echocardiography.
  • To assess changes in longitudinal, radial, and circumferential strain and strain rate post-transplantation.
  • To differentiate between HTR with and without TVP.

Main Methods:

  • Retrospective analysis of 41 HTR immediately and 1-3 years post-transplant.
  • 2D speckle tracking echocardiography to measure strain and strain rate.
  • Coronary angiography used for TVP diagnosis in seven cases.

Main Results:

  • Global longitudinal strain improved overall in HTR post-transplant (p=0.036).
  • Longitudinal strain did not significantly differ in patients who developed TVP.
  • Radial strain and torsion tended to decrease over time in HTR, including those with TVP.

Conclusions:

  • Speckle tracking imaging is valuable for assessing cardiac function in HTR.
  • While strain parameters show changes, coronary angiography is still essential for definitive TVP diagnosis.
  • Further research may refine the role of echocardiography in managing TVP.