Related Experiment Video
Updated: Apr 17, 2026

Characterization of Metabolic Status in Nonhuman Primates with the Intravenous Glucose Tolerance Test
Published on: November 13, 2016
Individuals with impaired glucose tolerance demonstrate normal cardiac sympathetic innervation using I-123 mIBG
O Asghar1, P Arumugam2, I S Armstrong2
1Institute of Cardiovascular Sciences, University of Manchester & Manchester Heart Centre, Central Manchester Foundation Trust, Manchester, United Kingdom. omar.asghar@manchester.ac.uk.
Background:
Impaired glucose tolerance (IGT) is associated with an increased risk of type 2 diabetes (T2DM) and cardiovascular disease. Some but not all studies have reported cardiac autonomic dysfunction in subjects with IGT and there is only one direct study of cardiac innervation in subjects with IGT. The purpose of this study was to assess global and regional cardiac sympathetic innervation and cardiac autonomic function in individuals with IGT.
Methods And Results:
We undertook (123)I-mIBG scintigraphy and cardiac autonomic function in 15 subjects with IGT and 15 age and sex-matched healthy controls. Early heart to mediastinum ratio (HMR) (1.71 ± 0.17 vs 1.67 ± 0.13, P = .49), late HMR (1.73 ± 0.18 vs 1.73 ± 0.16, P = .97) and washout rate (WR) (18.6 ± 4.2 vs 19.1 ± 7.6%, P = .84), did not differ between subjects with IGT and control subjects. More detailed regional analysis revealed reduced tracer uptake at the apex, base and inferior wall in all subjects and the anterior wall in a minority of subjects. There were no differences in total score (56.6 ± 4.0 vs 53.3 ± 8.4, P = .193), modified score (48.5 ± 3.3 vs 46.2 ± 6.0, P = .215), anterior wall score (10.2 ± 1.3 vs 10.1 ± 1.6, P = .898), inferior wall score (8.9 ± 1.9 vs 7.7 ± 2.6, P = .163), basal score (18.7 ± 1.9 vs 18.2 ± 3.3, P = .636) and tests of cardiac autonomic function between the groups.
Conclusion:
Global and regional measures of MIBG uptake and washout as well as cardiac autonomic function did not differ between subjects with IGT and healthy controls.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT

![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)