Purpose:
The purpose of this study was to determine the frequency/significance of incorrectly planned oblique T2-weighted (T2W) MRI of rectal adenocarcinoma.
Methods:
Eighty-six consecutive patients underwent MRI for rectal cancer staging. Two radiologists evaluated oblique T2W imaging and tumor stage.
Results:
A total of 71% of middle/high tumors had correctly planned oblique T2W-MRI. Thirteen of 14 low tumors (N=7) or tumors spanning at least two rectal segments (N=7) had incorrectly planned oblique T2W-MRI. The sensitivity/specificity of staging on correct compared to incorrect oblique T2W was: 88.9/50% (R1)/77.8/60% (R2) and 80/100% (R1)/60/80% (R2), (P=.54). Agreement was substantial, K=0.67.
Conclusions:
Oblique T2W-MRI is incorrectly performed in low tumors and those spanning multiple rectal segments. In this study, planning errors did not impact staging accuracy.
More Related Videos
06:54MR Molecular Imaging of Prostate Cancer with a Small Molecular CLT1 Peptide Targeted Contrast Agent
Published on: September 3, 2013
12:45Robot-assisted Total Mesorectal Excision and Lateral Pelvic Lymph Node Dissection for Locally Advanced Middle-low Rectal Cancer
Published on: February 12, 2022
Related Concept Videos
Imaging Studies IV: Magnetic Resonance Imaging
Magnetic Resonance Imaging