Low Cost Magnetic Resonance Imaging-Compatible Stepper Exercise Device for Use in Cardiac Stress Tests

Omid Forouzan1, Evan Flink1, Jared Warczytowa1

  • 1Department of Biomedical Engineering, University of Wisconsin-Madison , Engineering Centers Building, 1550 Engineering Drive, Madison, WI 53706

Journal of Medical Devices
|February 21, 2015
PubMed

Insights

A new, low-cost, MR-compatible stepper exercise device enables cardiac stress testing during MRI. This innovation allows for accurate assessment of cardiovascular function and disease progression in various conditions.

Area of Science:

  • Cardiovascular Imaging
  • Medical Devices
  • Exercise Physiology

Background:

  • Cardiovascular disease is a leading global cause of mortality.
  • Cardiac stress testing is crucial for diagnosing many cardiovascular conditions.
  • Existing exercise devices compatible with cardiac MRI are limited.

Purpose of the Study:

  • To develop and evaluate a novel, low-cost, magnetic resonance (MR) compatible exercise device.
  • To assess the feasibility of using this device for cardiac stress testing during MR imaging.
  • To enable noninvasive assessment of cardiovascular function under exercise conditions.

Main Methods:

  • Development of a low-cost stepper exercise device with adjustable weight resistance and MR compatibility.
  • Integration of electronics for power output measurement.
  • Pilot testing with healthy subjects performing leg-stepping exercise within an MR imager.

Main Results:

  • The MR-compatible stepper successfully induced significant exercise-related changes in heart rate (+42%), cardiac output (+40%), and mean pulmonary artery flow (+49%).
  • High-quality imaging was maintained during exercise.
  • The device demonstrated adjustability for different body sizes and ease of setup.

Conclusions:

  • The developed MR-compatible stepper exercise device is effective for inducing a hemodynamically stressed state suitable for cardiac MRI.
  • Its adjustable resistance caters to varying exercise capacities.
  • This low-cost device holds potential for diagnosing and monitoring cardiovascular pathologies requiring stress testing.

Related Concept Videos

Exercise Stress Test01:26

Exercise Stress Test

Introduction
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
2.1K
Imaging Studies for Cardiovascular System IV: CMRI01:21

Imaging Studies for Cardiovascular System IV: CMRI

Cardiovascular magnetic resonance imaging, or CMRI, is a non-invasive diagnostic test that employs a magnetic field and radiofrequency waves to create precise images of the heart and arteries. It provides comprehensive information about cardiac anatomy, function, perfusion, and tissue characterization without ionizing radiation.IndicationsCMRI diagnoses various heart conditions, including tissue damage from heart attacks, ischemic heart disease, myocarditis, aortic issues (tears, aneurysms,...
555
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
10.5K