Related Experiment Video
Updated: Apr 17, 2026

qPCR Is a Sensitive and Rapid Method for Detection of Cytomegaloviral DNA in Formalin-fixed, Paraffin-embedded Biopsy Tissue
Published on: July 9, 2014
Disposable immunosensor for human cytomegalovirus glycoprotein B detection
F Pires1, H Silva1, O Domínguez-Renedo2
1CICS-UBI - Health Sciences Research Centre, University of Beira Interior, 6200-506 Covilhã, Portugal; Department of Chemistry, University of Beira Interior, 6200-001 Covilhã, Portugal.
Abstract:
Combining the advantages of the biosensor field with the problem of detecting Human Cytomegalovirus (HCMV) in human samples, an inexpensive, simple and disposable electrochemical immunosensor for glycoprotein B detection in urine is proposed. Glycoprotein B has been chosen once is the dominant antigen of HCMV. The approach is based on a sandwich-type immunoassay, with the HCMV glycoprotein B sandwiched between the Anti-HCMV antibody adsorbed onto the working electrode, and the Anti-HCMV labeled with gold nanoparticles. Glycoprotein B detection was carried out through electrochemical stripping analysis of silver nanoparticles quantitatively deposited on the immunosensor through catalysis by the nanogold labels. The influence of different steps in the immunosensor construction, namely the silver deposition time, silver enhancer concentration, antibody concentration, BSA concentration and glycoprotein B incubation time, were examined and optimized. The method showed a linear dependence between glycoprotein B concentration and the corresponding anodic stripping peak current, resulting in detection limits of 3.3±1.7ng/mL for samples prepared in buffer and 3.2±0.2ng/mL for urine samples, suggesting that the biological matrix does not interfere with the immunosensor detection capability. Given its mode of preparation, by physical adsorption of the capture antibody in the working electrode, the immunosensor also exhibited an acceptable reproducibility, with a residual standard deviation of 13.5% for samples prepared in buffer and 11.2% for urine samples, thereby presenting a promising development potential for clinical applications.
More Related Videos
10:32A Miniaturized Glycan Microarray Assay for Assessing Avidity and Specificity of Influenza A Virus Hemagglutinins
Published on: May 29, 2016
08:21Cell-Free Dot Blot as a Practical and Adaptable Immunoassay Platform for the Detection of Antibody Response in Human and Animal Sera
Published on: May 23, 2025
Related Concept Videos
Cytomegalovirus Disease
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...