Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
An ultrasonographic technique to assess the jugular venous pulse: a proof of concept
Francesco Sisini1, Mirko Tessari2, Giacomo Gadda1
1Department of Physics and Earth Sciences, University of Ferrara, Ferrara, Italy.
Abstract:
The purpose of the work described here was to investigate the feasibility of assessing the jugular venous pulse (JVP) using ultrasound (US) equipment. Three young healthy subjects underwent a B-mode US scan of the internal jugular vein (IJV) to acquire a sonogram sequence in the transverse plane. On each acquired sonogram, the IJV contour was manually traced, and both the cross-sectional area (CSA) and the perimeter were measured. The CSA data set represents the US jugular diagram (USJD). The arterial distension waveform of the subjects was compared with its USJD. The correlation between the CSA and the perimeter was assessed during the cardiac cycle to verify IJV distension. For each subject, a short sonogram sequence of a few seconds was recorded, and the USJD obtained exhibited periodic behavior. Furthermore, for all subjects, the CSA was found to be correlated with the perimeter (Pearson coefficient, R > 0.9), indicating that the IJV in supine position is distended. We compared 390 manually traced contours of the IJV cross-sectional area with corresponding values semi-automatically calculated by an algorithm developed in-house. For all subjects, the sensitivity, specificity and accuracy were around 95%, 85% and 90% respectively. We found that a diagram reflecting the JVP can be obtained by analyzing a B-mode sonogram sequence of the IJV; such a diagram can result in a new methodology to assess the IJV functionality.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Ultrasonography
During an ultrasonography procedure, a handheld device called...