Background:
Diglycidyl ether of bisphenol A resin (DGEBA-R) is the most common sensitizer in epoxy systems, but a minority of patients also develop contact allergy to reactive diluents.
Objectives:
To analyse the frequency and clinical relevance of allergic reactions to different epoxy reactive diluents and related aliphatic epoxy resins.
Methods:
Test files (January 1991 to June 2014) were screened, and the clinical records of patients with allergic reactions were analysed for occupation, concomitant allergic reactions, and exposure.
Results:
A total of 67 patients reacted to at least one of the compounds. The largest numbers of allergic reactions were to phenyl glycidyl ether (PGE; n = 41), 1,4-butanediol diglycidyl ether (BDDGE; n = 34), and p-tert-butylphenyl glycidyl ether (PTBPGE; n = 19). Ten of the patients did not have contact allergy to DGEBA-R. The reactions of 5 of these were related to the use of BDDGE-containing products. We found no significant exposure to PGE or PTBPGE in patients sensitized to them, but some of the patients had used cresyl glycidyl ether-containing products.
Conclusions:
Allergic reactions to reactive diluents and related aliphatic epoxy resins usually occurred together with reactions to DGEBA-R. BDDGE was the clinically most significant compound, and was the sole cause of occupational allergic contact dermatitis in 3 patients.