Related Experiment Video
Updated: Apr 17, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Variation in duplex peak systolic velocity measurement in a multi-site vascular service
P Normahani1, M Aslam2, G Martin2
1Department of Vascular Surgery, Imperial College School of Medicine, UK pn106@imperial.ac.uk.
Objective:
Duplex US (DUS) is increasingly utilised as a first-line investigation for the assessment of carotid disease. For clinical decision-making, DUS assessment must be accurate and reproducible to ensure reliability. We aimed to investigate the variability in peak systolic velocity (PSV) measurement in a multi-site vascular network.
Methods:
DUS measurements of PSV were taken from continuous and pulsatile flow, generated by a high fidelity phantom, by 12 experienced vascular scientists across four hospitals. Participants were blinded to the actual PSV value (50 cm/s).
Results:
We observed an average error of 13.2% (± 8.3) and 11.6% (± 7.5) in PSV measurements taken from pulsatile and continuous waveforms, respectively. Measurements of PSV using the pulsatile waveform demonstrated statistically significant variation across all hospitals; ((hospital/mean) A 43.9 cm/s, B 61.7 cm/s, C 57.4 cm/s, D 47.7 cm/s, p=0.001). Further analysis demonstrated statistically significant variation in 4 instrumentation-related factors when measuring from a pulsatile waveform (Doppler angle, angle of insonation, velocity range, scale range).
Conclusion:
We observed a significant level of error and variation in PSV measurements across four sites within our vascular network. Variation in instrumentation-related factors may be accountable for this. In light of the centralisation of vascular services, it is increasingly important to unify and implement scanning protocols in order to reduce error and inter-site variability.
More Related Videos
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Pulse
The pulse serves as a clinical...

