Ten-year results from the Natrelle 410 anatomical form-stable silicone breast implant core study
G Patrick Maxwell1, Bruce W Van Natta1, Bradley P Bengtson1
1Dr Maxwell is a Clinical Professor at the Department of Plastic Surgery, Loma Linda University School of Medicine, Loma Linda, California, and an Assistant Clinical Professor at the Department of Plastic Surgery, Vanderbilt University School of Medicine, Nashville, Tennessee. Dr Van Natta is a Clinical Associate Professor at the Department of Surgery, Indiana University School of Medicine, Indianapolis, Indiana. Dr Bengtson is an Associate Professor at the Department of Surgery, Michigan State University College of Human Medicine, Grand Rapids, Michigan. Ms Murphy is the Director of Clinical Development Submissions at Allergan, Inc., Santa Barbara, California.
Background:
Silicone breast implants have long been used for breast augmentation and reconstruction. During this time, these medical devices have gone through a number of modifications to improve their safety, quality, and clinical outcome performance.
Objectives:
The authors conducted a 10-year study to determine the safety and effectiveness of Natrelle 410 silicone breast implants.
Methods:
This prospective, multicenter study enrolled 941 subjects who were undergoing either augmentation, augmentation revision, reconstruction, or reconstruction revision. Data on complications, reoperations, explantations, and subject satisfaction were collected at annual clinic visits, and one-third of subjects underwent biennial magnetic resonance imaging (MRI) to screen for implant rupture. The authors used the Kaplan-Meier estimator to calculate risk rates for local complications, reoperations, and explantations.
Results:
Capsular contracture rates increased approximately 1% per year from the previously reported 6-year rates. The rates were significantly lower than those from the Natrelle round gel core study. The overall rate of confirmed ruptured implants in subjects who underwent MRI was 5.7%. Eleven late seromas were reported. The most common reason for explantation was a subject requesting a size or style change. Satisfaction rates remained high through 10 years, with most subjects saying they were somewhat or definitely satisfied with their implants.
Conclusions:
This 10-year prospective trial demonstrated the long-term safety and effectiveness of Natrelle 410 anatomical form-stable implants. The complication rates were low and the satisfaction rates were high. LEVEL OF EVIDENCE 1: Therapeutic.
More Related Videos
03:07Single-Port Robotic-assisted Transaxillary Breast-conserving Surgery: A Prospective, Single-arm, Non-randomized Phase IIa Clinical Trial
Published on: August 19, 2025
06:03Integrating Augmented Reality Tools in Breast Cancer Related Lymphedema Prognostication and Diagnosis
Published on: February 6, 2020
Related Concept Videos
Bioavailability Study Design: Healthy Subjects Versus Patients
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Imaging Studies II: Ultrasonography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography