Related Experiment Video
Updated: Apr 16, 2026

Measurement of Specific Mycobacterial Mistranslation Rates with Gain-of-function Reporter Systems
Published on: April 26, 2019
Near-miss transcription errors: a comparison of reporting rates between a novel error-reporting mechanism and a
David A South1, Jessica W Skelley2, Mary Dang3
1PGY1 Health-System Pharmacy Administration Resident, UNC Hospitals , Chapel Hill, North Carolina.
Purpose:
The medication use process comprises several steps. In institutions without full implementation of computerized prescriber order entry (CPOE), transcription is a critical step in this process. As focus is increasingly placed on identifying near-miss errors, this study aimed to compare near-miss transcription error (NMTE) reporting rates between an institution's formal reporting system and an NMTE reporting mechanism.
Methods:
Two NMTE reporting mechanisms were assessed for 3 months. These mechanisms included the institution's formal error-reporting system and a specific transcription error queue within the institution's order imaging software. Date, patient-care unit, and type of transcription error were recorded for each order image in the transcription error queue and for each transcription error reported formally. Following data collection, reporting rates for both systems were compared.
Results:
Data collection spanned 92 days and an estimated 460,000 medication orders. In total, 1,563 NMTEs were reported using the transcription error queue and 12 errors were reported via the formal reporting mechanism. Of the 1,563 errors identified via the transcription error queue, 325 (20.79%) were of an unknown type. Reporting rates (with unknown errors removed) were 0.27% and 0.0026% for the novel system and formal reporting system, respectively (P < .001).
Conclusion:
Significantly more NMTEs were reported utilizing the novel system compared with the formal reporting system.
Related Concept Videos
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Types of Reports II: Incident or Occurrence Report
Purposes:
In the healthcare industry, reports play a crucial role in documenting incidents within an agency. The primary objective of these reports is to ensure patient safety, uphold the...
Improving Translational Accuracy
Improving Translational Accuracy
Nonsense-mediated mRNA Decay
Usually, Upf3 binds to an Exon Junction Complex (EJC) at mRNA splice sites. If a ribosome fully translates the mRNA,...
Nonsense-mediated mRNA Decay

