Related Experiment Video
Updated: Apr 16, 2026

Utilizing a 3D Printed Laparoscopic Nissen Fundoplication Model to Shorten a Resident's Learning Curve
Published on: August 15, 2025
Validation of a patient-specific simulator for laparoscopic renal surgery
Kazuhide Makiyama1, Hiroyuki Yamanaka1, Daiki Ueno1
1Department of Urology, Yokohama City University Graduate School of Medicine, Yokohama, Kanagawa, Japan.
Objectives:
To describe and to validate a novel patient-specific virtual-reality based simulator for laparoscopic surgery.
Methods:
Three surgeons carried out 13 preoperative simulations at Yokohama City University Hospital, Yokohama, Kanagawa, Japan, from 2011 to 2012. The procedures included seven nephrectomies, four partial nephrectomies and two pyeloplasties. We evaluated whether the anatomies reproduced by the simulator matched those encountered during the actual operations. Furthermore, the surgeons were asked to use visual analog scales (from 1 to 5; higher scores are better) to evaluate the anatomical integrity and utility of the simulations, and their intraoperative confidence during the subsequent surgical procedures.
Results:
The simulator reproduced the patients' anatomies almost perfectly. Only a few minor mistakes were identified. Regarding the surgeons' evaluations of the system, the mean scores for the anatomical integrity and utility of the simulations, and the surgeons' intraoperative confidence were 3.4, 4.2 and 4.1, respectively. In all 13 cases, the surgeons were able to carry out preoperative training with ease, and they stated that the simulator was useful for producing preoperative images.
Conclusions:
A patient-specific simulator for laparoscopic renal surgery has been successfully developed. This system correctly reproduces anatomical structures, and it seems to be a useful preoperative training tool.