Variability and uncertainty of 18F-FDG PET imaging protocols for assessing inflammation in atherosclerosis:
Pauline Huet1, Samuel Burg2, Dominique Le Guludec2
1U1023 Inserm/CEA/Paris Sud University-ERL 9218 CNRS, CEA-SHFJ, Orsay, France IMNC UMR 8165 CNRS, Paris Sud University, Orsay, France; and.
Unlabelled:
PET with (18)F-FDG shows promise for the evaluation of metabolic activities in atherosclerotic plaques. Although recommendations regarding the acquisition and measurement protocols to be used for (18)F-FDG PET imaging of atherosclerosis inflammation have been published, there is no consensus regarding the most appropriate protocols, and the image reconstruction approach has been especially overlooked. Given the small size of the targeted lesions, the reconstruction and measurement methods might strongly affect the results. We determined the differences in results due to the protocol variability and identified means of increasing the measurement reliability.
Methods:
An extensive literature search was performed to characterize the variability in atherosclerosis imaging and quantification protocols. Highly realistic simulations of atherosclerotic carotid lesions based on real patient data were designed to determine how the acquisition and processing protocol parameters affected the measured values.
Results:
In 49 articles, we identified 53 different acquisition protocols, 51 reconstruction protocols, and 46 quantification methods to characterize atherosclerotic lesions from (18)F-FDG PET images. The most important parameters affecting the measurement accuracy were the number of iterations used for reconstruction and the postfiltering applied to the reconstructed images, which could together make the measured standardized uptake values (SUVs) vary by a factor greater than 3. Image sampling, acquisition duration, and metrics used for the measurements also affected the results to a lesser extent (SUV varying by a factor of 1.3 at most). For an acceptable SUV variability, the lowest bias in SUV was observed using an 8-min acquisition per bed position; ordered-subset expectation maximization reconstruction with at least 120 maximum likelihood expectation maximization equivalent iterations, including a point spread function model using a 1 mm(3) voxel size; and no postfiltering. Because of the partial-volume effect, measurement bias remained greater than 60%. The use and limitations of the target-to-blood activity ratio metrics are also presented and discussed.
Conclusion:
(18)F-FDG PET protocol harmonization is needed in atherosclerosis imaging. Optimized protocols can significantly reduce the measurement errors in wall activity estimates, but PET systems with higher spatial resolution and advanced partial-volume corrections will be required to accurately assess plaque inflammation from (18)F-FDG PET.
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)

