Lower limb pneumatic compression during dobutamine stress echocardiography in patients with normal resting wall
Zainab Abdel-Salam, Lawra Allam, Bassem Wadie
1Cardiology Department, Faculty of Medicine, Ain Shams University. wnammas@hotmail.com.
Background:
Pneumatic compression of the lower part of the body increases systemic vascular resistance and left ventricular afterload.
Aim:
We compared the diagnostic accuracy of dobutamine stress echocardiography (DSE) with pneumatic compression of the lower extremities, vs. standard DSE, for detection of angiographically significant coronary artery disease (CAD) in patients with normal baseline resting wall motion.
Methods:
We enrolled 70 consecutive patients with no resting wall motion abnormalities (WMA), who underwent DSE. DSE was repeated with pneumatic compression of the lower extremities three days after the initial standard DSE. A positive test was defined as the induction of WMA in at least two contiguous non-overlap segments at any stage of dobutamine infusion. Significant coronary stenosis was defined as ≥ 50% obstruction of ≥ 1 sizable artery by coronary angiography.
Results:
The mean age of the study cohort was 54.7 ± 9.9 years; 55.7% were females. Thirty-eight (54.3%) patients had significant CAD. The mean test duration was 15.8 ± 5.1 min for standard DSE and 11.7 ± 4.1 min for DSE with pneumatic compression. Analysis of standard DSE revealed sensitivity, specificity, and positive and negative predictive values of 81.6%, 90.6%, 91.2%, and 80.6%, respectively; overall accuracy was 85.7%. Analysis of DSE with pneumatic compression revealed sensitivity, specificity, and positive and negative predictive values of 89.5%, 87.5%, 89.5%, and 87.5%, respectively; overall accuracy was 88.6%.
Conclusions:
In symptomatic patients with suspected CAD referred for evaluation by DSE, who have no resting wall motion abnormalities, pneumatic compression of the lower extremities during DSE improved the sensitivity but slightly reduced the specificity for detection of angiographically significant CAD, compared with standard DSE. Moreover, it reduced the test duration.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...