Method for automatic adjustment of an insulin bolus calculator: in silico robustness evaluation under intra-day
Pau Herrero1, Peter Pesl1, Jorge Bondia2
1Centre for Bio-Inspired Technology, Institute of Biomedical Engineering, Imperial College London, London, United Kingdom.
Background And Objective:
Insulin bolus calculators are simple decision support software tools incorporated in most commercially available insulin pumps and some capillary blood glucose meters. Although their clinical benefit has been demonstrated, their utilisation has not been widespread and their performance remains suboptimal, mainly because of their lack of flexibility and adaptability. One of the difficulties that people with diabetes, clinicians and carers face when using bolus calculators is having to set parameters and adjust them on a regular basis according to changes in insulin requirements. In this work, we propose a novel method that aims to automatically adjust the parameters of a bolus calculator. Periodic usage of a continuous glucose monitoring device is required for this purpose.
Methods:
To test the proposed method, an in silico evaluation under real-life conditions was carried out using the FDA-accepted Type 1 diabetes mellitus (T1DM) UVa/Padova simulator. Since the T1DM simulator does not incorporate intra-subject variability and uncertainty, a set of modifications were introduced to emulate them. Ten adult and ten adolescent virtual subjects were assessed over a 3-month scenario with realistic meal variability. The glycaemic metrics: mean blood glucose; percentage time in target; percentage time in hypoglycaemia; risk index, low blood glucose index; and blood glucose standard deviation, were employed for evaluation purposes. A t-test statistical analysis was carried out to evaluate the benefit of the presented algorithm against a bolus calculator without automatic adjustment.
Results:
The proposed method statistically improved (p<0.05) all glycemic metrics evaluating hypoglycaemia on both virtual cohorts: percentage time in hypoglycaemia (i.e. BG<70 mg/dl) (adults: 2.7±4.0 vs. 0.4±0.7, p=0.03; adolescents: 7.1±7.4 vs. 1.3±2.4, p=0.02) and low blood glucose index (LBGI) (adults: 1.1±1.3 vs. 0.3±0.2, p=0.002; adolescents: 2.0±2.19 vs. 0.7±1.4, p=0.05). A statistically significant improvement was also observed on the blood glucose standard deviation (BG SD mg/dL) (adults: 33.5±13.7 vs. 29.2±8.3, p=0.01; adolescents: 63.7±22.7 vs. 44.9±23.9, p=0.01). Apart from a small increase in mean blood glucose on the adult cohort (129.9±11.9 vs. 133.9±11.6, p=0.03), the rest of the evaluated metrics, despite showing an improvement trend, did not experience a statistically significant change.
Conclusions:
A novel method for automatically adjusting the parameters of a bolus calculator has the potential to improve glycemic control in T1DM diabetes management.
Related Concept Videos
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
One-Compartment Open Model for IV Bolus Administration: General Considerations
The drug's presence in the body is defined by an equation representing the difference between the rates of drug entry and exit. Key parameters—elimination rate constant,...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Two-Compartment Open Model: IV Bolus Administration
The disparity between drug input and the sum of drug transfer rates between...