Longitudinal assessment of inflammation in recipients of continuous-flow left ventricular assist devices
Liza Grosman-Rimon1, Ira Jacobs2, Laura C Tumiati3
1Division of Cardiovascular Surgery, Peter Munk Cardiac Centre, University Health Network, University of Toronto, Toronto, Ontario, Canada; Faculty of Kinesiology and Physical Education, University of Toronto, Toronto, Ontario, Canada.
Background:
The long-term effects of continuous-flow left ventricular assist device (CF-LVAD) support on trends of inflammatory markers over time are unknown. We examined the hypothesis that the levels of inflammatory markers in CF-LVAD recipients are higher than in healthy controls and that these levels increase over time with long-term CF-LVAD support.
Methods:
We examined the levels of inflammatory markers longitudinally at baseline before CF-LVAD implantation and at 3, 6, and 9 months after implantation. We then compared the levels of inflammatory markers to those in a healthy control group.
Results:
Compared with baseline values before CF-LVAD implantation, left ventricular end-diastolic diameter (LVEDd) and left ventricular end-systolic diameter (LVESd) decreased significantly at 3, 6, and 9 months after CF-LVAD implantation. Brain natriuretic peptide (BNP) levels dropped significantly after CF-LVAD implantation but did not normalize. Improvements in ejection fraction at 3, 6, and 9 months after CF-LVAD implantation did not reach significance. Monocyte chemoattractant protein-1, interferon γ-induced protein, and C-reactive protein levels were higher in the CF-LVAD recipients at each of the time points (baseline before CF-LVAD implantation and 3, 6, and 9 months after implantation) compared with levels in healthy controls. In CF-LVAD recipients, serum interleukin-8, tumour necrosis factor-α, and macrophage inflammatory protein-β increased significantly at 9 months, and macrophage-derived chemokine increased at 6 months after CF-LVAD implantation compared with baseline.
Conclusions:
Despite improvements in LV dimensions and BNP levels, markers of inflammation remained higher in CF-LVAD recipients. High levels of inflammation in CF-LVAD recipients may result from heart failure preconditioning or the long-term device support, or both. Because inflammation may be detrimental to CF-LVAD recipients, future studies should determine whether inflammatory pathways are reversible.