Related Experiment Video
Updated: Apr 16, 2026

Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
Left ventricular assist device driveline infection and the frequency of dressing change in hospitalized patients
Lisa Wus1, MaryLou Manning2, John W C Entwistle3
1Thomas Jefferson University Hospital, 111 South 11th Street, Suite 5480N, Philadelphia, PA 19107, USA.
Objectives:
To determine if driveline infection is related to dressing change frequency in hospitalized adult patients with newly implanted left ventricular assist devices (LVAD).
Background:
Guidelines do not exist for the frequency of driveline exit-site dressing change in hospitalized patients resulting in wide variation in practice.
Methods:
A retrospective chart review was conducted on 68 patients implanted with a HeartMate II LVAD between August 2008 and September 2013 at an urban medical center.
Results:
No driveline infections were found. Frequency of the driveline dressing change varied from daily, three times a week, and weekly. The daily dressing change group was younger in age compared to the weekly group (p = 0.005) and three times a week group (p = 0.001). No other differences were found.
Conclusion:
Driveline infections do not appear to be related to the frequency of dressing change in this population. Our data and other studies on this topic thus far are too limited to draw definitive conclusions about optimal frequency of dressing change for infection prevention.
More Related Videos
06:10Utilizing Percutaneous Ventricular Assist Devices in Acute Myocardial Infarction Complicated by Cardiogenic Shock
Published on: June 12, 2021
05:18Implantation of Left Ventricular Assist Device (LVAD) in Juvenile Landrace Swine: A LVAD Implantation Model of Pediatric Heart Failure
Published on: January 16, 2026
Related Concept Videos
Endocarditis IV: Nursing Management
Cardiomyopathy V: Interprofessional Care
Endocarditis III: Medical Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Endocarditis I: Introduction