Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Glucose Homeostasis: Regulation of Blood Glucose01:02

Glucose Homeostasis: Regulation of Blood Glucose

5.5K
Carbohydrates consumed through foods are converted into glucose, a crucial energy source for the body. In the prandial state, high blood glucose levels stimulate the secretion of insulin from the pancreas. Insulin inhibits hepatic glucose production and stimulates glucose uptake and metabolism by muscle and adipose tissue. The excess glucose is converted into glycogen and stored in the liver and muscles.
During fasting, when blood glucose levels are low, the pancreas secretes glucagon. it...
5.5K
Hormones Regulating Blood Glucose01:16

Hormones Regulating Blood Glucose

9.1K
Insulin is released by beta cells of the pancreas when blood glucose levels are high. It facilitates glucose absorption and utilization in insulin-dependent cells with insulin receptors on their plasma membranes. Insulin promotes glucose uptake by increasing the number of glucose transport proteins in the cell membrane, allowing glucose to enter the cell. As a result, glucose utilization and ATP production are enhanced.
In addition to accelerating glucose uptake and utilization, insulin has...
9.1K
Glucose Homeostasis: Pancreatic Islets and Insulin Secretion01:27

Glucose Homeostasis: Pancreatic Islets and Insulin Secretion

3.2K
The pancreatic islets comprising only 1%-2% of the volume are highly vascularized and innervated mini-organs. They contain five endocrine cell types, including β cells that secrete insulin, which is synthesized as a single polypeptide chain, preproinsulin, processed to proinsulin, and finally to insulin and C-peptide. This process is complex and regulated, involving the Golgi complex, the endoplasmic reticulum, and the secretory granules of the β cell.
Insulin and C-peptide are...
3.2K
Microbial Biosensors01:17

Microbial Biosensors

70
Microbial biosensors are analytical devices that utilize living microbes to detect specific substances through measurable signals. These devices consist of two main components: biosensing organisms and signal-transducing elements. Biosensing organisms, such as Escherichia coli or Saccharomyces cerevisiae, are typically housed in multiwell plates connected to transducers, enabling rapid, real-time detection of target analytes.Signal Generation MechanismWhen a target analyte—such as...
70

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same authorSame journal

Transient Benign Ketosis Is Common in Type 1 Diabetes During Very-Low Carbohydrate States: Novel Data from Continuous Ketone Sensor.

Diabetes technology & therapeutics·2026
Same author

Comparing Automated Lyumjev® Delivery with Carbohydrate Counting, Qualitative Meal-Size Estimation, and Fully Closed-Loop in Type 1 Diabetes: A Pilot, Randomized, Crossover Trial.

Diabetes technology & therapeutics·2026
Same author

The protective effect of high-intensity interval exercise compared with continuous moderate exercise on glycaemic decline is more pronounced in the postabsorptive vs postprandial state in adults with type 1 diabetes: a randomised crossover trial.

Diabetologia·2026
Same author

Leveraging questionnaire-based physical activity levels (PAL) and the Goldberg method to evaluate the biological plausibility of self-reported energy intake: A doubly labeled water validation study.

American journal of epidemiology·2026
Same author

Barriers and Enablers to Diabetes Technologies Use Among Individuals With Type 1 Diabetes: A Scoping Review.

Diabetes, obesity & metabolism·2026
Same author

Effects of a 50% versus 100% pre-prandial insulin bolus reduction to improve glycemic safety during postprandial continuous and intermittent exercise in adults with type 1 diabetes treated with multiple daily injections.

Frontiers in endocrinology·2026
Same journal

Continuous Glucose Monitoring Metrics and Perinatal Outcomes in Pregnant Women with Type 2 Diabetes.

Diabetes technology & therapeutics·2026
Same journal

Invited Commentary: Using Large Clinical Databases.

Diabetes technology & therapeutics·2026
Same journal

Impact of Technology Introduction on Glycemic Control of People Living with Type 1 Diabetes in Belgium: An Observational, Real-World Study.

Diabetes technology & therapeutics·2026
Same journal

Differences in Achieving Stringent Glycemic Targets Among Youth with Type 1 Diabetes: A SWEET Registry Study.

Diabetes technology & therapeutics·2026
Same journal

<i>Letter:</i> "Nocturnal Hypoglycemia: Characterization with Continuous Glucose Monitoring in a Real-World Setting".

Diabetes technology & therapeutics·2026
See all related articles

Related Experiment Video

Updated: Apr 16, 2026

Measuring Glucose Uptake in Drosophila Models of TDP-43 Proteinopathy
07:07

Measuring Glucose Uptake in Drosophila Models of TDP-43 Proteinopathy

Published on: August 3, 2021

3.2K

Enhancing glucose sensor models: modeling the drop-outs.

Ali Emami1, Remi Rabasa-Lhoret, Ahmad Haidar

  • 11 Institut de Recherches Cliniques de MontrĂ©al , Montreal, Quebec, Canada .

Diabetes Technology & Therapeutics
|March 10, 2015
PubMed
Summary
This summary is machine-generated.

An enhanced glucose sensor model now accounts for sensor reading drop-outs, improving artificial pancreas system simulations. This new model offers more realistic glucose level fitting compared to existing methods.

More Related Videos

Glucose Uptake Measurement and Response to Insulin Stimulation in In Vitro Cultured Human Primary Myotubes
08:03

Glucose Uptake Measurement and Response to Insulin Stimulation in In Vitro Cultured Human Primary Myotubes

Published on: June 25, 2017

20.9K
Extracellular Glucose Depletion as an Indirect Measure of Glucose Uptake in Cells and Tissues Ex Vivo
10:35

Extracellular Glucose Depletion as an Indirect Measure of Glucose Uptake in Cells and Tissues Ex Vivo

Published on: April 6, 2022

3.4K

Related Experiment Videos

Last Updated: Apr 16, 2026

Measuring Glucose Uptake in Drosophila Models of TDP-43 Proteinopathy
07:07

Measuring Glucose Uptake in Drosophila Models of TDP-43 Proteinopathy

Published on: August 3, 2021

3.2K
Glucose Uptake Measurement and Response to Insulin Stimulation in In Vitro Cultured Human Primary Myotubes
08:03

Glucose Uptake Measurement and Response to Insulin Stimulation in In Vitro Cultured Human Primary Myotubes

Published on: June 25, 2017

20.9K
Extracellular Glucose Depletion as an Indirect Measure of Glucose Uptake in Cells and Tissues Ex Vivo
10:35

Extracellular Glucose Depletion as an Indirect Measure of Glucose Uptake in Cells and Tissues Ex Vivo

Published on: April 6, 2022

3.4K

Area of Science:

  • Biomedical Engineering
  • Computational Physiology

Background:

  • Artificial pancreas systems rely on computer simulations, necessitating accurate glucose sensor models.
  • Existing glucose sensor models do not account for reading drop-outs caused by physical pressure.
  • This study introduces an enhanced model addressing this limitation.

Purpose of the Study:

  • To develop and validate an enhanced glucose sensor model that incorporates sensor reading drop-outs.
  • To improve the realism and accuracy of artificial pancreas system simulations.

Main Methods:

  • Augmented an existing one-compartment glucose sensor model to include potential drop-outs.
  • Employed a Bayesian approach to estimate drop-out incidences and magnitudes alongside model parameters.
  • Utilized data from 15 individuals with type 1 diabetes undergoing an artificial pancreas study.

Main Results:

  • The enhanced model estimated an average of 1.71 drop-outs per day.
  • Model fit improved, with weighted residuals reduced from [-4%, 3%] to [-3%, 2%].
  • Deviance information criteria significantly decreased from 2739.72 to 1456.00, indicating better model performance.

Conclusions:

  • The enhanced glucose sensor model provides a more accurate fit for glucose levels.
  • This improved model facilitates more realistic simulations for artificial pancreas system assessment.
  • The findings support the use of this enhanced model in developing advanced diabetes management technologies.