Related Experiment Video
Updated: Apr 16, 2026

Clinical Application of 24 G Cannula Needle and 3-0 Polypropylene Suture in Vas Deferens Exploration
Published on: February 10, 2023
Vesicocervical fistula: rare complication secondary to intrauterine device (Lippes loop) erosion
Chandrakala Magudapathi1, Ramalingam Manickam, Kavitha Thangavelu
1Department of Obstetrics and Gynaecology, G. Kuppuswamy Naidu Memorial Hospital, Nethaji Road, Coimbatore, 641037, India, chandrakala_m@yahoo.com.
Abstract:
We report a case of vesicocervical fistula following intrauterine device (Lippes loop) erosion following insertion 45 years ago. Vesicocervical fistula was suspected clinically. Ultrasound and magnetic resonance imaging confirmed the presence of a foreign body. Biopsy and magnetic resonance imaging were performed to rule out malignancies of the urogenital tract. The fistula was managed by laparotomy, hysterectomy, and bladder flap closure. We report this case because of its rarity.