Comparative study of membranes induced by PMMA or silicone in rats, and influence of external radiotherapy

Erwan de Monès1, Silke Schlaubitz2, Hugo Oliveira3

  • 1INSERM U1026, Tissue Bioengineering, 146 rue Léo-Saignat, F-33000 Bordeaux, France; Univ. Bordeaux, 146 rue Léo-Saignat, F-33000 Bordeaux, France; Department of Otolaryngology - Head and Neck Surgery, Univ. Bordeaux, Place Amélie Raba Léon, F-33000 Bordeaux, France.

Acta Biomaterialia
|March 16, 2015
PubMed

Insights

Replacing stiff polymethyl methacrylate (PMMA) spacers with medical-grade silicone in induced membranes for bone defect reconstruction offers advantages. Silicone spacers are safe for radiotherapy, unlike PMMA, which can cause inflammation and reduce bone healing potential.

Area of Science:

  • Biomaterials Science
  • Regenerative Medicine
  • Orthopedic Surgery

Background:

  • The induced membrane technique is crucial for long bone defect reconstruction.
  • Polymethyl methacrylate (PMMA) spacers present challenges in removal after membrane formation.
  • Semi-flexible medical-grade silicone spacers offer a potential alternative to PMMA.

Purpose of the Study:

  • To compare the characteristics of membranes induced by PMMA versus silicone spacers.
  • To evaluate the impact of radiotherapy on these induced membranes.
  • To assess the safety and efficacy of silicone spacers in irradiated environments.

Main Methods:

  • Subcutaneous implantation of PMMA and silicone spacers in 28 rats.
  • Histological analysis of induced membranes for composition, vascularization, thickness, fibrosis, and inflammation.
  • Western blotting for VEGF and BMP-2 expression.
  • Alkaline phosphatase (ALP) expression analysis in human bone marrow-derived stem cell (HBMSC) cultures.

Main Results:

  • Non-irradiated membranes from both spacer types were organized and non-inflammatory.
  • Silicone-induced membranes remained stable after irradiation.
  • PMMA-induced membranes became thicker, inflammatory, and showed reduced osteogenic potential post-irradiation.
  • Irradiated membranes exhibited an overall reduced osteogenic potential.

Conclusions:

  • Medical-grade silicone is a safe and effective alternative to PMMA spacers for induced membrane formation, especially in patients undergoing radiotherapy.
  • Silicone spacers maintain membrane integrity and biocompatibility even after radiation exposure.
  • This finding has significant implications for reconstructive surgery in cancer patients.