Related Experiment Video
Updated: Jul 25, 2026

Agarose-based Tissue Mimicking Optical Phantoms for Diffuse Reflectance Spectroscopy
Published on: August 22, 2018
Characterisation of Elastic and Acoustic Properties of an Agar-Based Tissue Mimicking Material
M P Brewin1, M J Birch2, D J Mehta3
1Blizard Institute, Barts and The London School of Medicine and Dentistry, Queen Mary University of London, London, UK. mark.brewin@salisbury.nhs.uk.
Abstract:
As a first step towards an acoustic localisation device for coronary stenosis to provide a non-invasive means of diagnosing arterial disease, measurements are reported for an agar-based tissue mimicking material (TMM) of the shear wave propagation velocity, attenuation and viscoelastic constants, together with one dimensional quasi-static elastic moduli and Poisson's ratio. Phase velocity and attenuation coefficients, determined by generating and detecting shear waves piezo-electrically in the range 300 Hz-2 kHz, were 3.2-7.5 ms(-1) and 320 dBm(-1). Quasi-static Young's modulus, shear modulus and Poisson's ratio, obtained by compressive or shear loading of cylindrical specimens were 150-160 kPa; 54-56 kPa and 0.37-0.44. The dynamic Young's and shear moduli, derived from fitting viscoelastic internal variables by an iterative statistical inverse solver to freely oscillating specimens were 230 and 33 kPa and the corresponding relaxation times, 0.046 and 0.036 s. The results were self-consistent, repeatable and provide baseline data required for the computational modelling of wave propagation in a phantom.