Measuring Ascending Aortic Stiffness In Vivo in Mice Using Ultrasound
Published on: December 2, 2014
An Imageless Ultrasound Device to Measure Local and Regional Arterial Stiffness
Abstract:
Arterial stiffness (AS) has been shown to be an important marker for risk assessment of cardiovascular events. Local arterial stiffness (LAS) is conventionally measured by evaluating arterial distensibility at particular arterial sites through ultrasound imaging systems. Regional arterial stiffness (RAS) is generally obtained by evaluating carotid to femoral pulse wave velocity (cfPWV) through tonometric devices. RAS has a better prognostic value than LAS and cfPWV is considered as the gold standard of AS. Over the past few years our group has been developing ARTerial Stiffness Evaluation for Non-Invasive Screening (ARTSENS), an inexpensive and portable device to measure the LAS. It uses a single element ultrasound transducer to obtain A-Mode frames from the desired artery and is fully automated to enable a non-expert to perform measurements. In this work, we report an extension of ARTSENS to enable measurement of cfPWV that now makes it the only fully automatic device that can measure both LAS and RAS. In this paper, we provide a general review of the ARTSENS and compare it with other state-of-the-art AS measurement systems. cfPWV measurement using ARTSENS was cross-validated against SphygmoCor by successive measurements with both devices on 41 human subjects and excellent agreement between both devices was demonstrated (Coefficient of determination and, limits of agreement m/s). The inter-device correlation between ARTSENS and SphygmoCor was found to be better than other similar studies reported in the literature.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Measurement of Blood Pressure
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation