A Cognitive Fusion-guided Prostate Biopsy Using Multiparametric Magnetic Resonance Imaging and Transrectal Ultrasound
Published on: March 21, 2025
Minimum 6 mm core length is strongly predictive for the presence of glandular tissue in transrectal prostate biopsy
Hasan Yilmaz1, Seyfettin Ciftci2, Murat Ustuner1
1Department of Urology, School of Medicine, University of Kocaeli, Kocaeli, Turkey.
Introduction:
Prostate biopsy guidelines recommend that a prostate biopsy not containing glandular prostate tissue should be reported as inadequate. In the literature, there is a lack of any study that addresses the relationship between the length of biopsy cores and the absence of glandular prostate tissue. In this study, we aimed to determine whether a relationship exists between these parameters.
Materials And Methods:
We retrospectively evaluated 1,712 consecutive initial transrectal 12-core prostate biopsies. Individual cores were histologically categorized as glandular (benign or malignant) and non-glandular (rectal mucosa, periprostatic adipose tissue, prostatic or periprostatic fibromuscular tissue). Total number of evaluable cores ≤9, highly fragmented, incorrectly numbered or dried biopsies, patients with 5-α reductase inhibitory treatment were excluded.
Results:
We analyzed remaining 1,584 patients; 41.7 % had adenocarcinoma. A total of 19,144 cores were sampled. Non-glandular cores were found significantly shorter than glandular cores (p < 0.0001). The percentages of non-glandular cores were significantly higher at the base, apex and lateral biopsy sites (p < 0.0001). We found a 6-mm cutoff value for accurate prediction of glandular sampling with 80.2 % sensitivity and 78.7 % specificity. The risk of non-glandular sampling increased 15-fold in cores ≤6 mm (OR 14.91, 95% CI 13.20-16.83, p < 0.0001).
Conclusions:
Non-glandular sampling was directly associated with shorter core lengths. They were found significantly higher at the base, apex and lateral localizations. We found a 6-mm cutoff value for the prediction of non-glandular samples before the histologic evaluation. Below this value, the risk of non-glandular sampling increased 15-fold. We suggest it for prompt additional sampling during biopsy procedure.