Related Experiment Video
Updated: Apr 16, 2026

Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
A near infrared spectroscopy-based test of calf muscle function in patients with peripheral arterial disease
Brian Lindegaard Pedersen1, Niels Bækgaard1, Bjørn Quistorff2
1Department of Vascular Surgery, Rigshospitalet and Gentofte Hospital, Copenhagen, Denmark.
Abstract:
Background The study aims to test a new, simple, and reliable apparatus and procedure for the diagnostics and treatment evaluation of peripheral arterial disease (PAD). The test apparatus involves near infrared spectroscopy (NIRS) of a main part of the lower leg muscles during isometric flexion and extension of the ankle joint performed with the foot strapped in a specially designed pedal ergometer. Design To evaluate the reproducibility of the new test compared with an existing testing method of treadmill walking. Methods Eleven patients participated in the study: nine patients with claudication and two age-matched patients without claudication. Each patient was tested with an isometric ergometer pedal test and a treadmill test applying NIRS measurements of the anterior tibial and the gastrocnemius muscles (GAS). Tests were repeated three times with randomly selected intervals between individual test runs. Intraclass correlation constant (ICC) was used to describe reproducibility. The ICC was calculated using the area under the NIRS oxygenated hemoglobin (Hbox) curve, the initial velocity of the Hbox recovery curve, force measurements, and walking time. Results The ICC of the GAS was between 0.92-0.95 (foot-pedal) and 0.70-0.98 (tread mill) and of the anterior tibial muscle was between 0.87-0.96 (foot-pedal) and 0.67-0.79 (tread mill). Conclusion In this study, we contribute a new apparatus and test protocol for peripheral arterial disease (PAD) applying NIRS technique and controlled physical activity to evaluate the degree of muscle oxygenation under specific functionally relevant conditions. Thus, we have developed a clinically applicable "easy-to-do" exercise test of patients with chronic PAD which show high reproducibility.
More Related Videos
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018
09:33Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
Published on: December 19, 2024
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessing Blood pressure in the Leg
Preparation: